Sharp CD-K7000V Service Manual page 48

Video cd mini system
Table of Contents

Advertisement

CD-K7000V,CP-C7000
(4) PLL system check
When a disc is loaded, start play operation.
The HF waveform is normal, but the TOC data cannot be
read.
Check the PDO waveform. (Figure 48-1)
Check around pins 1~6 on IC2.
(5) Others
The HF waveform is normal and the time is displayed
normally, but no sound is produced. Or the sound
has dropouts.
Is pin 35 (C2F) on IC2 "L"?
1. When playing at normal speed
Check the peripheral circuit at pin 37 (DOUT) on IC2 and
the waveform (Figure 48-2).
If OK, check the unit.
Yes
Stopped
CH1=500mV
DC 10:1
PDO1
3
4
PDO2
T
FDO
1
=Filter=
Smoothing : ON
BW : FULL
No
There are too many error flags on a damaged disc which
makes error correction impossible.
Check again using a known good disc.
Stopped
CH1=2V
DC 10:1
T
1
DOUT
=Filter=
Smoothing : ON
BW : FULL
– 48 –
1999/04/05 17:33:17
CH3=1V
CH4=1V
DC 10:1
DC 10:1
=Offset=
=Record Length=
CH1 :
0.000V
Main :
100K
Mode : AUTO
CH2 :
0.0V
Zoom :
2K
Type : EDGE CH2
Delay :
CH3 :
0.00V
CH4 :
0.00V
Hold off :
Figure 48-1
T
1999/04/07 09:25:28
=Offset=
=Record Length=
=Trigger=
CH1 :
0.00V
Main :
1K
Mode : NORMAL
CH2 :
0.00V
Zoom :
100
Type : EDGE CH1
Delay :
CH3 :
0.00V
CH4 :
0.00V
Hold off :
Figure 48-2
500ms/div
(500ms/div)
NORM:20kS/s
CH1
v/DIV
500mV
=Trigger=
0.0ns
0.2µs
500ns/div
(500ns/div)
NORM:200MS/s
2.887ms
0.2µs

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp-c7000

Table of Contents