Operating instructions Radio Control System MS
Compact-V 9600 Baud
Transmitter
Transmitter
Receiver

Advertisement

loading

Summary of Contents for NBB Compact-V 9600 Baud

  • Page 1 NBB Controls + Components GmbH Flexibly designed complete solutions Radio Control Systems – Cable Control Systems – Infrared Control Systems Operating instructions Radio Control System MS Compact-V 9600 Baud Transmitter Transmitter Receiver...
  • Page 2 NBB Controls + Components GmbH...
  • Page 3: Table Of Contents

    Contents General information ..............4 Transmitter Nano-L SMJ 7,2 V ............ 6 Receiver Compact-V 9600 Baud ..........12 Accessories ................16 Technical documents ............... 20...
  • Page 4: General Information

    Disregarding these recommendations puts you and others in danger! NBB refuses any warranty and liability in such cases. The radio control system is used to control machines and transmit data. In explosive atmospheres or for the control of machines for the transport of persons it may not be used, unless specifically authorized by the manufacturer for this application.
  • Page 5 – Check regularly for worn parts. Warranty NBB grants a functional warranty of 12 months from the date of sale on all NBB radio control systems (transmitter, receiver, charger). Working hours and material costs are included in the warranty. Shipping costs shall be at the expense of the buyer.
  • Page 6: Transmitter Nano-L Smj 7,2 V

    NBB Controls + Components GmbH Transmitter Nano-L SMJ 7,2 V Variations Nano-L SMJ 7,2 V with 2 Joysticks Nano-L SMJ 7,2 V with 3 Joysticks Nano-L SMJ 7,2 V with Display and 2 Joysticks Nano-L SMJ 7,2 V with 6 Joysticks...
  • Page 7 1. Press in the locking pin If the NBB radio control system won’t be used for a long period of time, it is strongly recommended remove the battery from transmitter and charge the battery approx. every 4 weeks. This prevents deep discharge of the battery and enhances its service life.
  • Page 8 NBB Controls + Components GmbH Transmitter Nano-L SMJ 7,2 V Operation of the system > Switching the transmitter on and off Design with emergency stop – Unlock the emergency stop pushbutton by turning clockwise to switch on the transmitter. – Two acoustic signal sounds.
  • Page 9 > Channel number During operation the set channel can be displayed by pressing the “Frequency switching” key. Please refer to the technical documents for the exact position of the “On/Horn” and “Frequency switching” buttons. > Battery life warnings The quick blinking of the letter “L” in the display shows the end of the battery capacity. From this time the operation of the transmitter is approx.
  • Page 10 NBB Controls + Components GmbH Transmitter Nano-L SMJ 7,2 V Surface Mounted Joystick > Changing the Surface Mounted Joystick – Switch off the transmitter and remove the battery. – Loosen all 4 screws of the Surface Mounted Joystick with a Torx 10 screwdriver and remove the screws.
  • Page 11 FSK – Signal nach CCITT V.23 Baud rate 1.200 – 9.600 Baud (Bit/sec.) Range Up to 100 m (depending on environment) Operating voltage Battery 7.2 V NBB Current consumption 60 – 100 mA RF output < 10 mW ERP Protection class...
  • Page 12: Receiver Compact-V 9600 Baud

    NBB Controls + Components GmbH Receiver Compact-V 9600 Baud Variations Compact-VC Compact-VB Compact-VD Compact-VE Edition 12/15...
  • Page 13 Commissioning The receiver is connected by a connection cable or plug to the system to be controlled. Please observe the instructions of the system manufacturer when installing. We strongly recommend establishing this connection via a central, easily accessible plug connection (e. g. Tyco type (HTS) plug connection, series HE/HB/HN/HA, or a comparable one from a different manufacturer) to enable a fast and precise error diagnosis for servicing and to be able to remove the receiver without installation work.
  • Page 14 Receiver Compact-V 9600 Baud Function control To maintain operational safety, a regular function check of the NBB radio remote control is necessary. In single-shift day-to-day operation, we recommend performing this check at least once a week. Checking is possible by using the display lights provided on the receiver. Therefore, the transmitter must be set to the ready-to-operate state.
  • Page 15 Technical data Receiver Compact-V 9600 Baud Operating ambient temperature – 20 °C to + 70 °C Protection class IP 65 Receive frequency range See nameplate Data security Addressing each receiver by a separate, unique Binary bit combination >16 million options...
  • Page 16: Accessories

    NBB Controls + Components GmbH Accessories Battery 7.2 V and charger for 7.2 V battery NiMH battery (7.2 V) Charger for charging NiMH rechargeable batteries (7.2 V) Edition 11/15...
  • Page 17 Battery 7.2 V Completely charge the battery before initial use. The battery only has its maximum capacity after five complete charging and discharging procedures! Completely discharge the battery in the control unit before charging again. The charging time depends on the type of battery. It is normal for the battery to heat up during charging or over long periods of use.
  • Page 18 NBB Controls + Components GmbH Accessories Charger for charging NiMH rechargeable batteries (7.2 V) Display of the charging procedure via a DUO-LED: LED – continuously lights up green: STANDBY. Charger is ready for operation. Insert the battery in the battery compartment.
  • Page 19 Installation information Please refer to the drawing for the measurements for attachment. Measurements in mm Optional integrated charger (in receiver) Integrated charger (in receiver) for charging NiCd and NiMH rechargeable batteries (7.2 V). Alternatively the receiver (DC supply) can be equipped with an integrated charger. Quick charging (approx.
  • Page 20 NBB Controls + Components GmbH...
  • Page 21: Technical Documents

    Technical documents...
  • Page 26 CONNECTING PLAN Compact V-D Cable length: ~2,5m Serial no.: 9600120085 호기 O.H.C. #4 7.5TON+7.5TON Cable loop-no.: 3.400.7005 Model: (41 x 0,75mm²) Clutch housing-no.: Wiring diagram no.: Costumer: I-Remo Insert-no.: Insert-no.: Date: 24.07.2018 Name: O. Vetter Plug-no.: ;-;-;-;-;-;-;-;-; Clutch housing-no.: Relay board code: RECEIVER CONTROL CABLE SYSTEM...
  • Page 27 CONNECTING PLAN Compact V-D Serial no.: 9600120085 Model: RECEIVER CONTROL CABLE SYSTEM Terminal strip: Terminal strip no.: or plug socket: Wire no.:/Pin no.: Function: Common IN_POT 1 --- / K1.1 / OUT_X1 A / A+B / B (BCD Bit0) 19 / K1.1 / SW29/30 OUT_X2 A / A+B / B (BCD Bit1)
  • Page 28 DATASHEET TRANSMITTER Formular-Nr.: 154_engl SERIAL No.: 9600120085 Stand: 01-10/10 O. Vetter 31.07.2018 NAME: DATE: Transmitter: Nano-L SMJ 7,2 V NOTE: PART No.: BOARD TITLE: QUANTITY: korean frequency FREQUENCY BAND Active / Passive LBT-Mode Auto Off Charger pl_nl_smj_led_v1_4_v2_12.txt Firmware S_9600120085_v1_0.scd Config PROGRAM 1 Interpreter S_9600120085_v1_0.il2...
  • Page 29 DATASHEET RECEIVER Formular-Nr.: 154 SERIAL No.: 9600120085 Stand: 02-10/10 M. Göldner 24.07.2018 NAME: DATE: Receiver: Compact V-D NOTE: PART No.: BOARD TITLE: QUANTITY: FREQUENCY BAND korean frequency Active / Passive 0,5s Potted .H86 E_9600120085_v1_0.H86 PROGRAM 1 Parameter Factory-Init.txt PROGRAM 2 UPPER PART 2.250.1500 black...