WATER CONDENSATE DRAINAGE
Continuous Draining in Dehumidifier Mode
While using the unit in dehumidifier mode, continuous drainage is recommended.
1.
Unplug the unit from power source.
2.
Remove the upper drain plug cap.
Some residual water may spill so please have a pan to
collect the water.
3.
Connect the drain tube (included) to the upper drain
plug. See diagram.
4.
The water can be continuously drained through the
drain tube into a floor drain or bucket.
5.
Replace the drain plug cap.
6.
You can now turn on the unit.
IMPORTANT: It is NOT recommended to connect the drain hose for continuous drainage while the
unit is switched ON in Air Conditioning Cooling mode. Doing so can reduce the cooling efficiency
of the Portable Air Conditioner. Only drain the water condensate when the unit is switched off.
Continuous drainage is only suitable when the unit is set up in Dehumidifier mode.
Drain Tube (included):
Dia. 0.6" (1.6 cm)
Length: 23.6" (60 cm)