Maintenance - Craftsman 919.165370 Owner's Manual

Permanently lubricated portable
Hide thumbs Also See for 919.165370:
Table of Contents

Advertisement

Available languages

Available languages

Customer Responsibilities
Check Safety Valve
Drain Tank
cycles automatically when power
is on. When servicing, you may
be exposed to voltage sources,
compressed air, or moving parts.
Before servicing unit unplug or
disconnect electrical supply to
Pantone 165- Warning orange
the air compressor, bleed tank
of pressure, and allow the air
compressor to cool.
NOTE: See "Operation" section for
the location of controls.
To Check Safety Valve
does not work properly, over-
pressurization may occur, causing
air tank rupture or an explosion.
1.
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
Pantone 165- Warning orange
operates freely. If the valve
is stuck or does not operate
smoothly, it must be replaced
with the same type of valve.

MAINTENANCE

Before
each
use
Risk of Unsafe
Operation. Unit
Risk of Bursting.
If the safety valve
Daily
or after
each
use
To Drain Tank
1.
Set the On/Auto/Off lever to
"OFF".
2.
Turn the regulator knob counter-
clockwise to set the outlet
pressure to zero.
3.
Remove the air tool or accessory.
4.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
5.
Drain water from air tank by
opening drain valve on bottom of
tank.
air tank. If not drained, water will
corrode and weaken the air tank
causing a risk of air tank rupture.
6.
After the water has been drained,
close the drain valve. The air
Pantone 165- Warning orange
compressor can now be stored.
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, the
reinstalled.
15- ENG
Water will
condense in the
A08595

Advertisement

Chapters

Table of Contents
loading

Table of Contents