Model 123A24 Rocket motor ICP® pressure sensor, 1000 psi, 5 mV/psi, Helium bleed, Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
Assistance is needed to safely operate equipment PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
Page 3
CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
OPERATION MANUAL FOR HELIUM BLEED WATER-COOLED PRESSURE SENSORS Models 123A, 123A21, 123A22, 123A23, & 123A24 INTRODUCTION The series of sensors described in this guide is designed to measure dynamic pressures in intense thermal environments typified by rocket engine combustion chambers. These sensors feature...
OPERATION MANUAL FOR HELIUM BLEED WATER-COOLED PRESSURE SENSORS Models 123A, 123A21, 123A22, 123A23, & 123A24 NOTE: When attaching helium supply hose, do not torque hose fitting through helium tube on sensor. Back up fitting with wrench on 3/8 hex on helium hose fitting.
OPERATION MANUAL FOR HELIUM BLEED WATER-COOLED PRESSURE SENSORS Models 123A, 123A21, 123A22, 123A23, & 123A24 The Model 123A23 has a sensitivity of 0.5 mV/psi TIME CONSTANT and a full-scale range of 10,000 psi. During in-place calibration static methods (dead The Model 123A24 has a sensitivity of 5.0 mV/psi weight tester) may be used in a drift-free system by and a full-scale range of 1000 psi.
The only maintenance possible on the probe is maintaining of insulation resistance of the Model 123A Probe/Cable Assembly. Clean connectors with suitable solvent and dry. Contact factory for assistance should problems arise. ICP is a registered trademark of PCB Piezotronics Drawing Number: 21091 ECO: 45804 Revision:...
Page 10
3425 Walden Avenue, Depew, NY 14043 All specifications are at room temperature unless otherwise specified. In the interest of constant product improvement, we reserve the right to change specifications without notice. ® is a registered trademark of PCB Piezotronics, Inc.
Page 11
Neither it nor any reproduction thereof will be disclosed to others HELIUM INPUT, AN TYPE FITTING DESCRIPTION without the written consent of PCB Piezotronics Inc. 5/16-24 UNF-2A UPDATE TOLERANCE ON MOUNTING HOLE 45725 WATER TUBE, AN TYPE FITTING...