Page 1
VERSION 1.00 REDUNDANT MULTIPLE AUDIO CLOCK PROCESSOR...
Page 3
§1 Warranty MUTEC GmbH warrants the flawless performance of this product to the original buyer for a period of two (2) years from the date of purchase. If any failure occurs within the specified warranty period that is caused by defects in material and/or workmanship, MUTEC GmbH shall either repair or replace the product free of charge within 90 days.
Before first power-on we recommend to read the chapters INTRODUCTION and BRIEF INSTRUCTIONS to get to know the general functionality of id and to reach a fast system integration. Boxes which contain a triangle...
AES/EBUid, S/PDIF and optional standards. Increasing failure safety in clock distribution systems. Extensions iDdp A functional description of all options is iD basis unit with two redundant power supplies contained in the chapter titled EXTENSIONS. iD-WCO-4 4 x Word Clock output expansion iC-ALARM 3-way relais-coupled alarm signal interface >...
2 + 3 STATUS Indicators The three blue indicators show the lock status of the currently active clock source. The five red indicators show important system statuses of iD. 4 CURSOR Buttons All parameter and function settings are controlled using the four cursor buttons and the display.
A software for remotely controlling the device over LANs (Local-Area Networks) will be available in future. 9 OPTION This slot is provided for installing optional iD terminals. Refer to the iD EXTENSIONS chapter for a short description of extensions available cur- rently or in the future.
\\\\\\\\\\\\ I N S TALLAT I O N I N S TALLAT I O N I N S TALLAT I O N > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > Wiring the AES/EBU and S/PDIF interfaces Connect the AES/EBU interfaces with the help of balanced electrical Especially when working with high...
Display Menu Structure The entire menu structure is based on the logical flow of events when deploying the iD in a standard audio/video-studio environment. Therefore, starting with the menu main page, the menu pages have an ergonomically structured sequence and can thus be called successively by repeatedly pressing the up button.
2 When an arrow pointing to the right is displayed, pressing the right iD. Even changing output function set-tings button (ENTER) will provide access to the adjustable parameter of the will not impede the overall operation! individual functions.
LOCKED (status message) LOCKED indicates that the system has synchronized to the internal video When iD is running in GENERATOR reference generator or an externally applied clock signal. At the same time, mode the first blue LED, LOCK REF 1,...
The REF1-3 page allows for selecting the clock source of the internal synthe- always be assigned to REF1! This is sizer. The clock formats supported by iD are listed in the adjacent table. The critical for proper completion of the CYCLE- factory defaults are REF1 = INTERN, REF2 = NO REF, REF3 = NO REF.
Page 17
SYNC function menu automatically. Moving the cursor to this e-mail message to position and pressing the ENTER button will activate the synchronization tecsupport@MUTEC-net.de process to the new clock source immediately. You may also call us or send a fax:...
The WCLK OUT1–8 display pages allow for configuring the eight wordclock Due to the internal signal phase corrections outputs provided by the iD standard version. Eight output pairs comprising the synthesizer can re-lock temporarily when one top-row and one bottom-row output each are available on the rear switching Word Clock clock frequencies.
This does not affect the output signals or 4 4 . 1 k 2 4 B I T P R O F functionality of iD. AES/EBU outputs page FREQ (function) FREQUENCY Sets the clock rate of the AES/EBU output pair. A so-called During DISTRIBUTOR operation, AES/EBU clear-frame signal (compliant to AES 11-1997/2003) is generated.
This does not affect the output signals or 4 4 . 1 k 2 4 B I T C O N S functionality of iD. S/PDIF outputs page FREQ (function) FREQUENCY Sets the clock rate of the S/PDIF outputs. A so-called S/PDIF During DISTRIBUTOR operation, clear frame signal (in compliance with AES11) is generated.
Setting System Functions System parameters allow for setting functions that affect no specific output clock formats but all output signals or the global device functionality of iD. Three menu pages named GLOBAL 1/3 to GLOBAL 3/3 are provided by iD‘s standard version.
Page 22
RESET This function allows for resetting all function or parameter changes 1) Press the ENTER button and hold. to their respective factory defaults, i.e. to the settings of the iD when it is 2) Press the up button additionally. switched on for the first time.
Page 23
POWER SUPPLY This informs on the status of the internal power supplies If one of the statuses 1-FAIL or and shows how many of them are active. The iD standard version is shipped 2-FAIL is indicated (iDdp only), with one power supply while the iDdp version contains two power supplies safe operation is not guaranteed! to ensure redundant (failsafe) operation.
Especially in cases of the later described SEQSYNC or CYCLESYNC functions, SoftReLock guarantees a gradual and seamless synchronization update of the internal signal generators, or all iD output signals respectively, to the basic clock rate of a new or reestablished reference source. Also if different reference types are synchronized in succession, e.g.
Example activating the REF1–3 menu page. It indicates the standard reference synchronization function of iD. The timing of this process is aligned to the If the first source (REF1) has failed, the syn- parameter adjustments of the LONEREF (Lock Next Reference) and thesizer tries automatically to synchronize LOCKTIME (Lock Time) functions (see GLOBAL 2/4 page).
\\\\\\\\\\\\ AP P E N D I X AP P E N D I X AP P E N D I X > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > Pin Assignment of the Connectors Mains CAUTION! Disconnect the unit from...
Remount the steel-plate cover thoroughly before you attempt to operate Ground connectors J 15, J 16 the unit! When iD is shipped, the BNC-based universal in- Jumper: puts are isolated to ground to avoid interference from the connected clock line.
\\\\\\\\\\\\\\\\\\ A N H A N G A N H A N G A N H A N G > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > Technical Data UNIVERSAL SYNC INPUTS Interfaces...
Page 31
Weight: iDdp ~ 3100g OPTIONS iD dp iD with double power supplies and double power inputs, Part no. 8015-061 iC – ALARM Relay-coupled alarm signal output expansion, Part no. 8005-065 iD – WCO4 4 x Word Clock output expansion, Part no. 8005-080...