Mutec iD Operating Manual

Redundant multiple audio clock processor

Advertisement

Quick Links

VERSION 1.00
REDUNDANT MULTIPLE
AUDIO CLOCK PROCESSOR

Advertisement

Table of Contents
loading

Summary of Contents for Mutec iD

  • Page 1 VERSION 1.00 REDUNDANT MULTIPLE AUDIO CLOCK PROCESSOR...
  • Page 3 §1 Warranty MUTEC GmbH warrants the flawless performance of this product to the original buyer for a period of two (2) years from the date of purchase. If any failure occurs within the specified warranty period that is caused by defects in material and/or workmanship, MUTEC GmbH shall either repair or replace the product free of charge within 90 days.
  • Page 5: Table Of Contents

    CONTROL ELEMENTS iD Front Panel ......9 iD + iD dp Rear Panels ..... 9 INSTALLATION Content of the Box .
  • Page 7: About This Manual

    Before first power-on we recommend to read the chapters INTRODUCTION and BRIEF INSTRUCTIONS to get to know the general functionality of id and to reach a fast system integration. Boxes which contain a triangle...
  • Page 8: Features

    AES/EBUid, S/PDIF and optional standards. Increasing failure safety in clock distribution systems. Extensions iDdp A functional description of all options is iD basis unit with two redundant power supplies contained in the chapter titled EXTENSIONS. iD-WCO-4 4 x Word Clock output expansion iC-ALARM 3-way relais-coupled alarm signal interface >...
  • Page 9: Id Front Panel

    2 + 3 STATUS Indicators The three blue indicators show the lock status of the currently active clock source. The five red indicators show important system statuses of iD. 4 CURSOR Buttons All parameter and function settings are controlled using the four cursor buttons and the display.
  • Page 10: Control Elements

    A software for remotely controlling the device over LANs (Local-Area Networks) will be available in future. 9 OPTION This slot is provided for installing optional iD terminals. Refer to the iD EXTENSIONS chapter for a short description of extensions available cur- rently or in the future.
  • Page 11: Installation

    Always be sure to connect the Word Clock outputs of iD to the accord- the same, as this is the only way to...
  • Page 12: Wiring The Aes/Ebu And S/Pdif Interfaces

    \\\\\\\\\\\\ I N S TALLAT I O N I N S TALLAT I O N I N S TALLAT I O N > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > Wiring the AES/EBU and S/PDIF interfaces Connect the AES/EBU interfaces with the help of balanced electrical Especially when working with high...
  • Page 13: Operation

    Display Menu Structure The entire menu structure is based on the logical flow of events when deploying the iD in a standard audio/video-studio environment. Therefore, starting with the menu main page, the menu pages have an ergonomically structured sequence and can thus be called successively by repeatedly pressing the up button.
  • Page 14: Selecting Menu Pages And Setting Functions

    2 When an arrow pointing to the right is displayed, pressing the right iD. Even changing output function set-tings button (ENTER) will provide access to the adjustable parameter of the will not impede the overall operation! individual functions.
  • Page 15: Main Menu Page

    LOCKED (status message) LOCKED indicates that the system has synchronized to the internal video When iD is running in GENERATOR reference generator or an externally applied clock signal. At the same time, mode the first blue LED, LOCK REF 1,...
  • Page 16: Selecting The Mode Of Operation

    The REF1-3 page allows for selecting the clock source of the internal synthe- always be assigned to REF1! This is sizer. The clock formats supported by iD are listed in the adjacent table. The critical for proper completion of the CYCLE- factory defaults are REF1 = INTERN, REF2 = NO REF, REF3 = NO REF.
  • Page 17 SYNC function menu automatically. Moving the cursor to this e-mail message to position and pressing the ENTER button will activate the synchronization tecsupport@MUTEC-net.de process to the new clock source immediately. You may also call us or send a fax:...
  • Page 18: Configuring The Word Clock Outputs

    The WCLK OUT1–8 display pages allow for configuring the eight wordclock Due to the internal signal phase corrections outputs provided by the iD standard version. Eight output pairs comprising the synthesizer can re-lock temporarily when one top-row and one bottom-row output each are available on the rear switching Word Clock clock frequencies.
  • Page 19: Configuring The Aes/Ebu Outputs

    This does not affect the output signals or 4 4 . 1 k 2 4 B I T P R O F functionality of iD. AES/EBU outputs page FREQ (function) FREQUENCY Sets the clock rate of the AES/EBU output pair. A so-called During DISTRIBUTOR operation, AES/EBU clear-frame signal (compliant to AES 11-1997/2003) is generated.
  • Page 20: Configuring The S/Pdif Outputs

    This does not affect the output signals or 4 4 . 1 k 2 4 B I T C O N S functionality of iD. S/PDIF outputs page FREQ (function) FREQUENCY Sets the clock rate of the S/PDIF outputs. A so-called S/PDIF During DISTRIBUTOR operation, clear frame signal (in compliance with AES11) is generated.
  • Page 21: Setting System Functions

    Setting System Functions System parameters allow for setting functions that affect no specific output clock formats but all output signals or the global device functionality of iD. Three menu pages named GLOBAL 1/3 to GLOBAL 3/3 are provided by iD‘s standard version.
  • Page 22 RESET This function allows for resetting all function or parameter changes 1) Press the ENTER button and hold. to their respective factory defaults, i.e. to the settings of the iD when it is 2) Press the up button additionally. switched on for the first time.
  • Page 23 POWER SUPPLY This informs on the status of the internal power supplies If one of the statuses 1-FAIL or and shows how many of them are active. The iD standard version is shipped 2-FAIL is indicated (iDdp only), with one power supply while the iDdp version contains two power supplies safe operation is not guaranteed! to ensure redundant (failsafe) operation.
  • Page 24: Id Technology

    Especially in cases of the later described SEQSYNC or CYCLESYNC functions, SoftReLock guarantees a gradual and seamless synchronization update of the internal signal generators, or all iD output signals respectively, to the basic clock rate of a new or reestablished reference source. Also if different reference types are synchronized in succession, e.g.
  • Page 25: Sequence Synchronization

    Example activating the REF1–3 menu page. It indicates the standard reference synchronization function of iD. The timing of this process is aligned to the If the first source (REF1) has failed, the syn- parameter adjustments of the LONEREF (Lock Next Reference) and thesizer tries automatically to synchronize LOCKTIME (Lock Time) functions (see GLOBAL 2/4 page).
  • Page 26: Id Extensions

    > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > iD EXTENSIONS iC-ALARM The optional iC-ALARM interface (ordering no.
  • Page 27: Appendix

    B E D I E N E L E M E N T E B E D I E N E L E M E N T E B E D I E N E L E M E N T E >...
  • Page 28: Pin Assignment Of The Connectors

    \\\\\\\\\\\\ AP P E N D I X AP P E N D I X AP P E N D I X > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > Pin Assignment of the Connectors Mains CAUTION! Disconnect the unit from...
  • Page 29: Connecting The Universal Clock Inputs To Ground

    Remount the steel-plate cover thoroughly before you attempt to operate Ground connectors J 15, J 16 the unit! When iD is shipped, the BNC-based universal in- Jumper: puts are isolated to ground to avoid interference from the connected clock line.
  • Page 30: Technical Data

    \\\\\\\\\\\\\\\\\\ A N H A N G A N H A N G A N H A N G > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > Technical Data UNIVERSAL SYNC INPUTS Interfaces...
  • Page 31 Weight: iDdp ~ 3100g OPTIONS iD dp iD with double power supplies and double power inputs, Part no. 8015-061 iC – ALARM Relay-coupled alarm signal output expansion, Part no. 8005-065 iD – WCO4 4 x Word Clock output expansion, Part no. 8005-080...
  • Page 32 > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > WWW.MUTEC-NET.DE FON 0049-(0)30-746880-0 ALL SOFTWARE AND HARDWARE PRODUCT NAMES ARE REGISTERED TRADEMARKS OF THEIR RESPECTIVE OWNERS. FAX 0049-(0)30-746880-99 WE RESERVE THE RIGHT TO CHANGE TECHNICAL DETAILS WITHOUT PRIOR NOTICE. © MUTEC GmbH 2002 • 7045-014...

This manual is also suitable for:

Id dp

Table of Contents