Amoul i5 User Manual

Amoul i5 User Manual

Automatic external defibrillator

Advertisement

User Manual
Automatic External Defibrillator
Release Version:A2.2
Revision date:2022.10.12
User Manual of i5 Automatic external defibrillator

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the i5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Amoul i5

  • Page 1 User Manual of i5 Automatic external defibrillator User Manual Automatic External Defibrillator Release Version:A2.2 Revision date:2022.10.12...
  • Page 3: Table Of Contents

    User Manual of i5 Automatic external defibrillator Contents Contents ..............................1 Product information ..........................2 Intellectual Property Right ........................3 Statement ..............................4 Return ..............................6 Equipment Description ........................... 8 Warning、Attention and tips ........................8 1 Equipment description ........................11 1.1 Purpose ............................11 1.2 Indication ..........................
  • Page 4: Product Information

    User Manual of i5 Automatic external defibrillator Product information Thanks for purchasing i5 Automatic external defibrillator. To use the instrument correctly, please carefully read and understand the Manual before using. Keep the manual properly after reading and put it in an accessible position.
  • Page 5: Intellectual Property Right

    User Manual of i5 Automatic external defibrillator Intellectual Property Right © 2022 AMBULANC (SHENZHEN) TECH.CO.,LTD. All rights reserved. This product operating manual intellectual property AMBULANC(SHENZHEN) TECH.CO.,LTD., including but not limited to patent right, trademark right and copyright. Ambulanc technology company has the final right to interpret this manual.
  • Page 6: Statement

    User Manual of i5 Automatic external defibrillator Statement Ambulanc technology company reserves the right to modify this manual without prior notice. Ambulanc technology company reserves the right to change related technology without prior notice. Ambulanc technology company reserves the right to alter product specification without prior notice.
  • Page 7 User Manual of i5 Automatic external defibrillator Maintenance Service Scope of Charge-Free Service: • Charge-free service is provided for any equipment in the range of Ambulanc technology company warranty terms. Scope of Paid Service: • Paid service is provided for any equipment beyond the range of Ambulanc technology company warranty terms.
  • Page 8: Return

    User Manual of i5 Automatic external defibrillator Warranty Manufacturing Process and Raw Material: Ambulanc technology company warrants that no failure will be resulted from any defect in manufacturing process or raw material when this instrument is used and serviced correctly.
  • Page 9 User Manual of i5 Automatic external defibrillator Important Information After purchase of the product, the customer shall take full responsibility for maintenance and management of it. Quality assurance will not cover the following even during the warranty period: • any damage or loss resulted from improper use or misuse of the product;...
  • Page 10: Equipment Description

    User Manual of i5 Automatic external defibrillator 12. Ambulanc technology company will not bear the cost of transportation if the warranty request is rejected. 13. Ambulanc technology company takes no responsibility for damage or loss resulted from negligence or failure to observe the preventive measures stated in this manual.
  • Page 11 • Keep i5 away from sources of electromagnetic interference (such as motors, generators, X-ray equipment, radio transmitters, cellular mobile phones, nuclear magnetic resonance, and other equipment) as it may interfere with the signals being collected and analyzed during operation. .
  • Page 12 User Manual of i5 Automatic external defibrillator • In order to avoid contamination or infection of personnel, the environment or other equipment, equipment and its accessories that meet the service life must be disposed of in accordance with relevant local regulations or hospital systems :...
  • Page 13: Equipment Description

    1 Equipment description 1.1 Purpose i5 is an Automatic external defibrillator. Simple and direct voice prompt and indication are provided for direct rescue operation. The equipment is light, powered by battery and convenient to carry. i5 aims to treat ventricular fibrillation (VF) and ventricular tachycardia, and these two symptoms are the most common cause for sudden cardiac arrest (SCA).
  • Page 14: Installation And Setting

    2.2 CPR setting Tips: i5 provides voice prompt (1min and 30s, 1min, 40s and 20s) of rest time under the pause time countdown mode till the next cycle of defibrillation (start from ECG analysis). Under the pause time countdown mode, press the flashing blue "i" within 20s after CPR start to start the CPR voice guide mode.
  • Page 15: Defibrillation

    Warning: Please don't use i5 for children below 1 year old. Tips: i5 can be used for children at the age of 1-8. • Please use the pediatric low-energy defibrillator electrode supplied by Ambulanc technology company for children at the age of 1-8 or the weight is less than 25Kg. (Please don't use the pediatric low-energy defibrillator electrode supplied by Ambulanc technology company for adult patients.)
  • Page 16: Cpr Guide

    It will recover the ECG analysis automatically after CPR. • If it is necessary to use other defibrillators for the patient, please disconnect i5 from the patient. Before using other defibrillators, please disconnect the connection between i5 and the patient.
  • Page 17 User Manual of i5 Automatic external defibrillator data. If it is necessary to remove the battery, please shut down i5 correctly before removal by pressing "Start/shutdown". • i5 has≥16G memory capacity for recording ECG and rescue data. If the collected data exceeds the capacity during rescue, it will cover the earlier data automatically.
  • Page 18: Sanitary Treatment

    • Please don't soak the parts of i5 in the liquid. • If i5 is soaked in water, please contact with Ambulanc technology company or its authorized representative to provide maintenance service. • Please prevent liquid from entering the equipment box.
  • Page 19: Maintenance

    Please dispose battery according to the local laws and regulations. • Please don't put i5 battery in unsafe environment. 5.3 Defibrillator electrode Warning: • Only the electrodes supplied by the manufacturer can be used for supporting i5. Use of JG-205-3-SP031(2.0)
  • Page 20: Technical Parameter

    Resolution Pixel: 800 x 480 7 EMC 7.1 Declaration of magnetic radiation i5 can be used for the following specific electromagnetic environment, and the user shall use the equipment in the following specified electromagnetic environment. Compliance Radiation test Electromagnetic environment guide...
  • Page 21: Declaration Of Electromagnetic Immunity - Requirements For All Equipment Systems

    (IEC 61000-3-3) 7.2 Declaration of electromagnetic immunity - Requirements for all equipment systems i5 can be used for the following specific electromagnetic environment, and the user shall use the equipment in the following specified electromagnetic environment. Category of 60601-1...
  • Page 22: Declaration On Guide And Manufacturer - Electromagnetic Immunity

    30V/m 80 MHz-2.5 GHz Electromagnetic environment guide The portable and mobile RF communication equipment shall not be used near i5 than the recommended isolation distance, including cable. The distance is calculated according to the formula of transmitter frequency. Recommended isolation distance:...
  • Page 23: Recommended Isolation Distance

    RF transmitter, consider the survey of electromagnetic place. If the field intensity of i5 is higher than the RF conformance level, observe i5 to verify whether it can work normally. If normal performance is observed, the supplementary measures may be necessary, for example, readjust the direction or position of i5.
  • Page 24: Storage And Transportation

    User Manual of i5 Automatic external defibrillator 6.765MHz-6.795MHz, 13.553MHz-13.567MHz, 26.957MHz-27.283MHz and 40.66MHz-40.70MHz. Note 3: Additional factor 10/3 is used for calculating the recommended isolation distance of transmitter on the medical engineering frequency band (150kHz-80MHz) and in the frequency range of 80MHz-2.5GHz, so as to reduce the probability of interference caused by portable/mobile RF communication equipment when being taken to the patient area.
  • Page 25 Address: 3F, 5# Building C, Skyworth Innovation Valley, Tangtou No.1 Road, Shiyan Street, Bao'an District, Shenzhen City Postal code: 518108 Tel.: +86-75526072210 Fax: +86-75523016012 Website: http://www.amoulmed.com Email: manager@amoulmed.com...

Table of Contents

Save PDF