  • Page 1 Code 501274 AWC30HP Air Compressor Axminster Tool Centre, Unit 10 Weycroft Avenue, Axminster, Devon EX13 5PH axminster.co.uk...
  • Page 2: Safety Precautions

    10. Do not adjust the tank pressure switch without Model Number RAC3050E (Air Compressor) to the compressor. reference to Axminster Tool’s Service Department. 3. Always check oil level before using the 11. Do not remove parts from the compressor whilst compressor.
  • Page 3: Specification

    Report any compressor oil, (see our catalogue). The oil level problems to Axminster Tool Centre’s Customer should be just below the (MAX) marker on the dip Services Department. Fit the wheels and the Rubber stick.
  • Page 4: Illustration And Parts Description

    Assembly Assembly Tube Handle Assembly Locate the tube handle (M) and the two grub screws place using the two grub screws (L). Tighten with the Oil Filler Plug Dipstick (L). Slide the ends of the tube handle into the two supplied 4mm Hex key .
  • Page 5 Illustration and Parts Description Illustration and Parts Description Cylinder Motor cover Air inlet filter Reset button Air filter assembly Tube handle On/Off switch Pressure switch Regulator adjusting knob Outlet pressure gauge Tank pressure gauge Pressure relief valve Tank Crankcase Check valve Front foot Wheel Water drain valve...
  • Page 6: Maintenance

    Operating Instructions Maintenance The outlet air pressure can be regulated by rotating Weekly: plug and vey carefully drain the oil out. (See fig G) the regulator knob (A) clockwise to increase the Replace drain plug and refill to the level mark on the pressure and anticlockwise to reduce it.
  • Page 7: Parts Breakdown

    Parts Breakdown Parts List Item Description Item Description Cowl Pressure guage Cylinder gasket Motor Quick release adaptor Capacitor Regulated valve assembly Capacitor plate Connector Oil cleaning ring Pressure switch assembly Short discharge pipe Locking nut Right-angle tee Safe valve assembly Bolt Handle Cylinder...
  • Page 8: Troubleshooting

    Carefully clean all sealing surfaces before re-assembling The compressor Crank bearing failure Stop the compressor and contact Axminster does not reach the Tool Centre set pressure and overheats The compressor is Pressure switch Stop the compressor quickly.
  • Page 9 Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local recycling centre and place into the appropriate recycling bin. Only for EU countries Do not dispose of electric tools together with household waste material.