3TA1EG10 / 3TA1EG30 / 3TW1EG30
4a
See chart for Torque
[ Ver torque en tabla ]
Wire Connector
Wire Size
[ Conexión del
[ Rango Cable ]
cable ]
14 -10 AWG
[ 2.5 – 6 mm² ]
8 AWG
[ 10 mm² ]
6 - 4 AWG
[ 16 – 25 mm² ]
3 - 2 AWG
3TA1EG10
( Cu / Al )
[ 35 mm² ]
1 – 1 / 0 AWG
[ 50 mm² ]
6 – 2 AWG
[ 16– 35 mm² ]
3TA1EG30
1 – 3 / 0 AWG
( Cu / Al )
[ 50 – 95 mm² ]
14 -10 AWG
[ 2.5 – 6 mm² ]
8 AWG
[ 10 mm² ]
6 - 4 AWG
[ 16 – 25 mm² ]
3TW1EG30
3 - 2 AWG
( Cu Only )
[ 35 mm² ]
1 – 3 / 0 AWG
[ 50 – 95 mm² ]
Technical Support:
Subject to change without prior notice
Siemens Industry, Inc. , Norcross, GA U.S.A.
Tensión peligrosa.
Tensión peligrosa.
Puede causar la muerte o lesiones graves.
Puede causar la muerte o lesiones graves.
Desenergice totalmente antes de instalar o darle servicio.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
energizar el interruptor.
Torque Lugs without cables
4b
[ Para bornes sin cables ]
1X
10 – 15 Lbs. in.
[ 1.1 – 1.7 Nm ]
Req. Wire Stranding
[ Hebras ]
[ esfuerzo de torsión ]
UL 486A - 486B
Torque Lugs with cables
CU
CU / AL
[ Para bornes sin cables ]
Class B
Class C
7
19
19
37
19
7
19
37
19
OK
37
Toll Free: 1-800-964-4114
3 / 3
3 / 3
Tension dangereuse.
Tension dangereuse.
Danger de mort ou risque de blessures graves.
Danger de mort ou risque de blessures graves.
Couper l'alimentation de l'appareil et barrer avant de
Couper l'alimentation de l'appareil et barrer avant de
travailler.
travailler.
Remplacez touts les couverts avant que
Remplacez touts les couverts avant que
l'approvisionnement de pouvoir soit alimenté.
l'approvisionnement de pouvoir soit alimenté.
Torque Lugs without cables
[ Para bornes sin cables ]
3X
10 – 15 Lbs. in.
[ 1.1 – 1.7 Nm ]
Wire Strip
Torque
Length
[ Quitar ]
35 Lb. in.
[ 4.0 Nm ]
40 Lb. in.
[ 4.5 Nm ]
45 Lb. in.
.5"
[ 13mm ]
[ 5.1 Nm ]
50 Lb. in.
[ 5.6 Nm ]
50 Lb. in.
[ 5.6 Nm ]
.5"
80 Lb. in.
[ 13mm ]
[ 9.0 Nm ]
35 Lb. in.
[ 4.0 Nm ]
40 Lb. in.
[ 4.5 Nm ]
.5"
45 Lb. in.
[ 5.1 Nm ]
[ 13mm ]
50 Lb. in.
[ 5.6 Nm ]
50 Lb. in.
[ 5.6 Nm ]
Internet: www.usa.siemens.com/powerdistribution