Service information – Disassembly
* Refer to service manual for more details
Remove the turntable sheet,
turntable and head shell.
Put a cushion such as what
is used for packing products,
to fix the tone arm
Fix tone arm with
completely.
the arm clamp
Phono Equalizer circuit
Need
Remove 2 screws
No need to
unsoldering
remove
(5 cables)
Turn the unit upside down, place it
on a thick pad or dust cover and
remove screws.
Release the arm
lock.
Release the arm lock and then
pull it up.
Technical Information for Hi‐Fi Audio System