TECHNICAL NOTE
st
Date 1
Aug 18 (rev 3 Sept 19)
ref 418
Raised by: TC
Distributed to: as required
Soundtracs - Digico(UK) Ltd. unit 10 Silverglade Business Park Chessington Surrey KT9 2QL England
Tel: +44 1372 845600 Fax: +44 1372 845656 email: support@digiconsoles.com
SD7-QUANTUM MIXER
Use of HORM system and overview screen setup

Introduction to HORM

HORM - Hibernate Once Read Many - is a Windows 7e function an equivalent to Ready On as
used on the older SD-series consoles based on Win XPe.
The functionality of this is slightly different. In the same way as Ready On, it protects the C:\ Drive
from unintended changes.
The method of making intended changes is quite different to the older system and is described
below.
The main difference that is immediately seen between HORM and Ready-On is that there is no
command line path to start an application on startup.
*In the case of a corrupted startup.ses preventing the console starting up correctly, holding the
SHIFT key will still offer the option of a "default start". Hold the SHIFT key as soon as you see the
SD7 logo appear on the Master screen
External Monitor (EDID) registration & connection
External (overview) monitors connected with DVI connections all have a unique serial number
which the mixer OS must register. This is done ONE time only, for each monitor to be connected
to any given mixer (each engine independently) The OS HORM protection prevents registration
and must be switched off to enable the monitor to function.
The DVI-2 connection on the engine is covered in TN459. If used, the overview should be setup
first, before attempting to use DVI-2. The DVI-Test output is not used in normal operation and no
attempt should be made to connect to this.
Unlike other mixers in the SD series the external monitor is NOT connected to the mixer before
power up, before the first use. Should this be done the displays will usually arrange themselves to
a default setting meaning only the master screen is visible and others show an empty desktop.

Use of HORM system

The access the HORM system quit to Windows from the mixer program.
When working in Windows on SD7, always quit BOTH engines to Windows before further actions.
Touch "Quit to Windows" under the system button.
Click on the start button on the Windows task bar
See the selection of programs available
TN 418
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SD7-QUANTUM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for digico SD7-QUANTUM

  • Page 1 418 Raised by: TC Distributed to: as required Soundtracs - Digico(UK) Ltd. unit 10 Silverglade Business Park Chessington Surrey KT9 2QL England Tel: +44 1372 845600 Fax: +44 1372 845656 email: support@digiconsoles.com SD7-QUANTUM MIXER Use of HORM system and overview screen setup...
  • Page 2 Click on SD7Q HORM This will open the HORM operating window, showing that HORM protection is active (ON) Click “OFF” the engine will immediately shut down and restart. This about ½ minute to complete The engine will return to Windows and HORM window showing “OFF” is active Protection is now disabled and adjustments in the operating system can be made.
  • Page 3 Right click on the desktop, see desktop menu open and click on SD7Q Screen Settings See the screen setup page open. Ensure the screen layout is as follows. If the layout of screen is not as shown this must be set. With a new screen it may default to a horizontal spread.
  • Page 4 It is possible to repeat this process with several different examples of overview screens and the operating system will detect and remember settings for each screen, so long as the HORM protection is disabled. If the same screen is used again, the setup will be recalled automatically without further adjustment.

Table of Contents