Page 1
E1715S 1. Disassembly Procedures: Step Figure Remark Turn off power, Unplug external cables from product S1. Remove the STAND BASE ASS'Y. Note: Put the monitor on a flat, soft and clean surface. Press the button on the red circle then pull out the stand follow the arrow, stand-base assy will be remove.
Page 2
E1715S Use a Philips-head screwdriver to remove 6 screws for unlocking mechanisms. (No.1~2 screw size=M4x10; Torque=12±2kgf.cm No.5~6 screw size=P3x4; Torque=6±1kgf.cm) S2. Remove the REAR COVER. Use Penknife to separate the bezel and rear cove follow the arrows in sequence, then you can...
Page 3
E1715S Disconnect the key board S3. Remove the Cable. harness. S4. Disconnect the LED HARNESS and FFC CABLE. Push Push...
Page 4
E1715S 1. Turn over the main frame. 2. Remove the Insulating sheet. Use a Philips-head screwdriver to remove 4 screws for unlocking Main board and Power board (No.1~3 screw size=M3x6; Torque=6±1kgf.cm S5. Remove No.4 screw the MAIN and size=M4x6; POWER Torque=6±1kgf.cm)...
Page 5
E1715S S6. Disconnect the HARNESS. S7. Remove the MAIN FRAME S8. Remove the PANEL from Bezel...
Page 6
E1715S Use a Philips-head screwdriver to remove 4 S9. Remove screws for unlocking Key the KEY board BOARD. (No.1~4 screw size=M2x2.5; Torque=0.7±0.2kgf.cm) Remove electrolyte capacitors (red mark) from printed circuit boards S10.Remove capacitors Take out bulk cap. pin solder with soldering...
Page 7
E1715S Lift the bulk cap. up and away from the PCB...
Page 8
E1715S 2. Product material information The following substances, preparations, or components should be disposed of or recovered separately from other WEEE in compliance with Article 4 of EU Council Directive 75/442/EEC. Capacitors / condensers (containing No used PCB/PCT) Mercury containing components...