Troubleshooting - ITech AT21-132001 Owner’s Manual And Operation Instruction

3200 starting watts/3000 running watts portable inverter generator
Table of Contents

Advertisement

Problem
Generator will not start
Generator will not start;
Generator starts but runs roughly
Generator shuts down during operation
Generator cannot supply enough power or
overheating
No AC output
Repeated circuit breaker tripping

TROUBLESHOOTING

Cause
No fuel
Faulty spark plug
Unit loaded during start up
Low oil level
Choke in the wrong position
Spark plug wire loose
Out of fuel
Low oil level
Generator is overloaded
Insuf cient ventilation
Cable not properly connected
Connected device is defective
Circuit breaker is open
Loose wiring
Other
Overload
Faulty cords or device
30
Solution
Add fuel
Replace spark plug
Remove load from unit
Fill crankcase to the proper level
Place generator on a at, level surface
Adjust choke
Attach wire to spark plug
Fill fuel tank
Fill crankcase to the proper level. Place
generator on a at, level surface
Review load and adjust. See "Power
Management"
Check for air restriction. Move to a well
ventilated area
Check all connections
Replace defective device
Reset circuit breaker
Inspect and tighten wiring connections
Contact the help line
Review load and adjust. See "Power
Management"
Check for damaged, bare or frayed wires.
Replace defective device

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AT21-132001 and is the answer not in the manual?

Table of Contents