Battery Replacement
1. Remove the spark plug wire from spark plug.
2. Remove the nut and bolt from the negative(-) and positive(+) posts.
3. Loosen and remove the screw A and nut B on the battery holding bracket.
4. Remove the battery and recycle and dispose of properly.
5. Install the new battery with follwoing specification:
12V sealed lead acid 7.5AH
LXWXH: 5.95X2.55X3.82inch (151X65X97mm)
6. Connect the red positive(+) battery cable to the battery first.
7. Connect the black positive(-) battery cable to the battery second.
8. Cover the post with boots.
9. Install the spark plug wire onto spark plug.
Battery Charging
The battery powers the control module. This portable generator is equipped with an automatic
battery charging circuit. The battery will receive charging voltage only when the engine is running.
The battery will maintain a proper charge if the portable generator is used on a regular basis
(about once every two weeks). If it is used less frequently, the battery should be connected to a
trickle charger (not included) or battery maintainer (not included) to keep the battery properly
charged.