10. Allow portable generator to run at no load for a few minutes to stabilize before plugging in
any electrical devices.
NOTICE If engine starts but fails to run, or if portable generator shuts down during operation,
check oil level. See Low Oil Shutdown section for more information.
4. Starting the Generator on LPG
1. Before starting the generator, check for loose or missing parts and for any damage which may
have occurred during shipment. Ensure spark plug, muffler, fuel cap, and air cleaner are all in place.
2. Move portable generator outdoors to safe operating location at least 20 feet (6 m) from any
occupied spaces.
3. Connect the LPG hose with regulator to both LPG cylinder and portable generator LPG Hose
Connector (inlet).
4. Fully open the LPG cylinder knob.
5. Turn the main fuel selector switch to LPG position.
NOTICE When the main fuel selector switch is turned to the LPG position, the indicator light
will turn RED for up to 4 minutes (before going off). Starting the engine successfully anytime
during the 4 minutes will turn the indicator light GREEN.
See Indicator light-Battery Power Saving Mode section for more information.
English
LPG
18
OPERATION
Customer Service: 1-844-FIRMAN1

Advertisement