Dual fuel generator

Advertisement

Indicator light - Battery Power Saving Mode
This generator is equipped with an electronic module which consumes battery power. When the
main fuel selector switch is turned to the GAS or LPG position, the indicator light will turn
RED for up to 4 minutes (before going off). Starting the engine successfully anytime during the 4
minutes will turn the indicator light GREEN. If portable generator is not started during this
4-minute period the portable generator will switch to Battery Power Saving Mode to conserve
battery life.
NOTICE Your portable generator is equipped with an internal battery charger that will properly
charge the battery only when the engine is running.
The generator cannot be started in Battery Power Saving Mode. Turn main fuel selector switch to
the off position and back to the GAS or LPG position to reset the RED indicator 4-minute
electronic module.
3. Starting the Generator on Gasoline
1. Before starting the generator, check for loose or missing parts and for any damage which may
have occurred during shipment. Ensure spark plug, muffler, fuel cap, and air cleaner are all in place.
2. Move portable generator outdoors to safe operating location at least 20
feet from any occupied spaces.
3. If connected make sure the LPG cylinder knob is fully closed or disconnected.
4. Turn the fuel selector switch to "GAS" position.
NOTICE When the fuel selector switch is turned to the GAS position, the indicator light will
turn RED for up to 4 minutes (before going off). Starting the engine successfully anytime during
the 4 minutes will turn the indicator light GREEN. See Indicator light-Battery Power Saving
Mode section for more information.