5.3
Body and Clamp Re-Assembly
1. Place the metal reinforced seal on lower filter body.
(Fig 4) Place upper filter body on metal reinforced
seal and lower filter body in a position which allows
all operation and safety labels to be clearly visible
and the upper filter body to be centered on the lower
filter body. Press down firmly and evenly on the upper filter body to seat the seal. (Fig 7)
2. Replace the filter clamp around the upper and lower filter bodies. Hold the clamp ends to position
the clamp on the filter bodies with the clamp ends adjacent to the safety and operation labels on
the filter bodies. (Fig 7)
3. Insert clamp bolt through the clamp ends and thread the clamp nut onto clamp bolt with
rounded end of the nut (Fig 8) towards the ends of the clamp.
4. Never rely on hand tightening of clamp nut to clamp bolt. Using a 3/4" socket on a torque
wrench, torque clamp nut to clamp bolt to 150 inch-lbs. (Fig 9)
WARNING : DO NOT HIT OR STRIKE CLAMP WITH HAMMER OR METAL TOOLS.
5. Follow Operation Instructions for "Starting the Pump and Filter System" (Page 5).
6. Vacuuming Pool
Vacuuming can be performed directly into the filter whenever needed.
Clean cartridges after vacuuming, if required.
10
TIGHTEN CLAMP BOLT AND NUT USING A TORQUE WRENCH
TO 150 INCH-LBS.
CLAMP BOLT
CLAMP NUT
Figure 9
7. Manual Air Relief Valve
7.1
Removing the Manual Air Relief Valve
WARNING
This product should be installed and serviced
only by a qualified pool professional.
Your Filter comes with a Manual Air Relief Valve (MAR)
pre-installed from the factory. For Qualified pool
professionals only: If MAR valve needs to be
serviced, follow these instructions carefully.
1. Turn off all system circulation pumps and all
electric power on the equipment pad.
2. Set all system valves in a position to prevent
Figure 10
from flowing to the filter.
3. The manual air relief valve must be placed in
MANUAL AIR RELIEF SHOWN OPEN IN LOCKED POSITON
the OPEN position.
4. Wait until all water leakage has stopped.
5. Grasp the MAR body at the flats, turn the MAR counterclockwise until the indicator on the on the
MAR flange is aligned with the "UNLOCK" position on the upper filter body.
6. Pull straight up to remove the MAR, a slight rocking motion may help.
7.2
Re-Installation of the Manual Air Relief Valve
This product should be installed and serviced only by a qualified pool professional.
1. Check the o-ring seals, replace as needed.
2. With a clean cloth, wipe upper filter body and o-ring groove. Remove all dirt and debris.
3. Align the notch in the MAR Flange with notch on top of the upper filter body.
4. Press the MAR straight down into the upper filter body.
5. Turn the MAR clockwise until the indicator is aligned with the "LOCK" position on the upper filter body.
6. Verify the MAR discharge points away from all electrical connections.
8. Winterizing Filter
WARNING
This product should be installed and serviced only by a qualified pool professional.
In areas where subfreezing temperatures can be expected, the filter should be drained to protect the
filter from damage.
1. The filter should be disassembled and the filter cartridges elements cleaned or replaced.
2. Follow directions under FILTER DISASSEMBLY INSTRUCTIONS
3. Then follow REMOVING CARTRIDGES per instructions
4. Reassemble per FILTER RE-ASSEMBLY INSTRUCTIONS.
5. Be sure to leave the drain plug unattached during the winter season to avoid cracking the filter body.