<Fig. 35> CCA Automatic Adjustment Set-up
16-3. Sequence of Adjustment
(1) Start the adjustment program (ccws.exe)
(2) Select the correct model in Work->Select_Model. (*cmf
file)
(3) Check 'Cool Inspection', Warm Inspection', Medium
Inspection'.
* One (Cool, Warm or medium) must be selected.
(4) Color Coordinate Value
X Coordinate
Cool
Warm
Medium
(5) Click Auto Measure.
-> There is a progress display in the right side of the 'Auto
CCA Progress' screen.
(Measurement is started automatically for automatically
to R->G->B->Y->C->Black->W OK, defective are
determined by readings in the lower right.)
(6) If the readings are good then the adjustment is over, If not
this procedure may have to be repeated up to three times.
<Fig. 36> CCA Automatic Adjustment Program Main Screen
Y Coordinate
278
279
315
316
287
289
16-4. Program Edit.
(1) Parameter Edit: Interval time and Target White
coordinates are between command words per Mode,
adjustable to correct a common difference. (Edit -->
Parameter Edit)
<Fig. 37> CCA Automatic Adjustment Program Main Screen
(2) Serial Edit: CA-210 and RS-232C Connection setting for
SET. (Edit --> Serial Edit)
±6
±6
±6
<Fig. 38> CCA Automatic Adjustment Program Main Screen
- 19 -