Philips BJ3.1E LA Service Manual page 31

Table of Contents

Advertisement

Service Modes, Error Codes, and Fault Finding
POD
transfer Wake up reasons to the
Stand by µP.
Images are re-transferred to DDR-RAM from
Flash RAM (verification through checksum)
MIPS image completes the application reload,
stops DDR-RAM access, puts itself in a
sleepmode and signals the standby µP when the
standby mode can be entered.
DDR-RAM is put in self refresh mode and the images
are kept in the hibernating DDR-RAM.
Wait 5ms
Switch Viper in reset state
Wait 10ms
Switch the NVM reset line HIGH.
Disable all supply related protections and switch off
the +2V5, +3V3 DC/DC converter.
Wait 5ms
switch off the remaining DC/DC converters
Switch OFF all supplies by switching HIGH the POD-
MODE I/O line.
Stand by
Figure 5-14 "POD" to "Stand-by" flowchart
BJ3.1E LA
action holder: MIPS
action holder: St-by
autonomous action
Important remark:
release reset audio and sound-
enable 2 sec after entering
standby to save power
G_15960_136.eps