Philips Q549.5E LA Service Manual page 30

Table of Contents

Advertisement

EN 30
5.
Q549.5E LA
Table 5-2 Error code overview
Description
2
I
C3
2
I
C2
PNX doesn't boot (HW cause)
PNX 51XX doesn't boot
12V
Inverter or display supply
1V2, 3V3, 5V to low
Temp protection
PNX 51XX
HDMI mux
2
I
C switch
Boot-NVM PNX51XX
Multi Standard demodulator
(Micronas IF)
ARM (ambilight)
FPGA (Local contrast)
Tuner
Fan I2C expander
T° sensor
FAN 1
FAN 2
Main NVM
PNX doesn't boot (SW cause) 2
Display (only 56PFL9954H)
Extra Info
Rebooting. When a TV is constantly rebooting due to
internal problems, most of the time no errors will be logged
or blinked. This rebooting can be recognized via a ComPair
interface and Hyperterminal (for Hyperterminal settings,
see section
"5.8 Fault Finding and Repair
Logging). It's shown that the loggings which are generated
by the main software keep continuing. In this case
diagnose has to be done via ComPair.
2
Error 13 (I
C bus 3 blocked). At the time of release of this
manual, this error was not working as expected. Current
situation: when this error occurs, the TV will constantly
reboot due to the blocked bus. The best way for further
diagnosis here, is to use ComPair.
Error 15 (PNX8543,PNX51XX doesn't boot). Indicates
that the main processor/PNX51XX was not able to read his
bootscript. This error will point to a hardware problem
around the PNX8543 (supplies not OK, PNX 8543
2
completely dead, I
Processor broken, etc...). When error 15 occurs it is also
2
possible that I
C1 bus is blocked (NVM). I
indicated in the schematics as follows: SCL-UP-MIPS,
SDA-UP-MIPS, SCL-1, SDA-1, SCL-2 or SDA-2.
Other root causes for this error can be due to hardware
problems from the NVM PNX51XX, DDR's and the
bootscript reading from the PNX51XX.
Error 16 (12V). This voltage is made in the power supply
and results in protection (LAYER 1 error = 3) in case of
absence. When SDM is activated we see blinking LED
LAYER 2 error = 16.
Error 17 (Invertor or Display Supply). Here the status of
the "Power OK" (INV_OK) is checked by software, no
protection will occur during failure of the invertor or display
supply (no picture), only error logging. Error LAYER 1 = 3
in CSM, in SDM this gives LAYER 2 error = 17.
Error 18 (1V2-3V3-5V too low). All these supplies are
generated by the DC/DC supply on the SSB. If one of these
supplies is too low, protection occurs and blinking LED
LAYER 1 error = 2 will be displayed automatically. In SDM
this gives LAYER 2 error = 18.
2009-Sep-11
Service Modes, Error Codes, and Fault Finding
Monitored
Layer 1 Layer 2
by
2
13
MIPS
2
14
MIPS
2
15
Stby µP
3
16
Stby µP
3
17
MIPS
2
18
Stby µP
3
12
MIPS
2
21
MIPS
2
23
MIPS
2
24
MIPS
2
25
MIPS
2
27
MIPS
8
28
MIPS
2
29
MIPS
2
34
MIPS
7
41
MIPS
7
42
MIPS
7
43
MIPS
7
44
MIPS
2
/
MIPS
53
Stby µP
5
64
MIPS
Tips,
5.8.6
C link between PNX and Stand-by
2
C1 can be
Error/
Error Buffer/
Prot
Blinking LED Device
E
BL / EB
SSB
E
BL / EB
SSB/Display
P
BL
PNX8543/PNX51XX
2
I
C blocked
P
BL
/
E
EB
/
P
BL
/
E
EB
/
E
EB
PNX5100
E
EB
TDA9996
E
EB
PCA9540
E
EB
STM24C08
E
EB
DRX3616K
DRX3626K
E
EB
NXP LPC2103
E
EB
Altera
E
EB
UV1783S/HD1816
E
EB
PCA9533
E
EB
LM 75
E
EB
E
EB
E
X
STM24C128
E
BL
PNX8543
E
BL / EB
Altera
Error 21 (PNX 51XX). When there is no I
communication towards the PNX51XX, the TV set will start
rebooting and display LAYER 1 error = 2. Disconnect the
mains cord now and start up the TV set with the solder path
(SDM) short to ground during start-up to activate the
LAYER 2 error blinking. Error "21" will be logged and
displayed via the blinking LED procedure after a few
moments from start-up. Remark: the rebooting can be
recognized via a ComPair interface and Hyperterminal (for
Hyperterminal settings, see section
Repair
Tips,
which are generated by the main software keep continuing.
Check in the logging for keywords like e.g. "Device
error 21".
Error 23 (HDMI). When there is no I
towards the HDMI mux after start-up, LAYER 2 error = 23
will be logged and displayed via the blinking LED
procedure if SDM is switched on. It should be noted that in
case a new spare EDID MUX device is used for repair, the
initial default address must be changed from "C0" to "CE",
to be done via ComPair.
2
Error 24 (I
C switch). When there is no I
communication towards the I
error = 24 will be logged and displayed via the blinking LED
procedure when SDM is switched on. Remark: this only
works for TV sets with an I
Error 25 (Boot-NVM PNX51XX). Same behaviour as
described in "Error 21 (PNX51XX)".
Error 27 (Micronas IF). When there is no I
communication towards the multi standard demodulator,
LAYER 2 error = 27 will be logged and displayed via the
blinking LED procedure if SDM is switched on.
Error 28 (ARM ambilight). When there is no I
communication towards the ARM processor, LAYER 2
error = 28 will be logged and displayed via the blinking LED
procedure if SDM is switched on.
Error 29 (FPGA local contrast). When there is no I
communication towards this FPGA, LAYER 2 error = 29
will be logged and displayed via the blinking LED
procedure if SDM is activated.
Defective Board
SSB
SSB/display
SSB
Supply
IPB1/IPB2
SSB
Display
SSB
SSB
SSB
SSB
SSB
AL module or DC/DC
SSB
SSB
FAN module
T° sensor
FAN
FAN
SSB
SSB
Display
2
C
"5.8 Fault Finding and
5.8.6
Logging"). It is shown that the loggings
2
C communication
2
C
2
C switch, LAYER 2
2
C controlled screen included.
2
C
2
C
2
C

Advertisement

Table of Contents
loading

Table of Contents