10.1 Cleaning and care
risk of explosion and/or fire due to ignition of an explosive atmosphere or of
combustible dust!
Serious injury caused by blast pressure and fire may result.
▶
The axial piston unit must not be cleaned with compressed air, solvents,
aggressive cleaning agents or high-pressure cleaners since these can result in
changes that could result in the loss of the explosion protection.
▶
Only clean the axial piston unit with a damp, lint-free cloth; cleaning with a dry
cloth could cause static electricity to build.
For cleaning and care of the axial piston unit, observe the following:
▶
Check whether all seals and plug-in connections are securely seated to ensure
no moisture can penetrate into the axial piston unit during cleaning.
▶
Use only water and, if necessary, a mild cleaning agent to clean
the axial piston unit. Never use solvents or aggressive cleaning agents.
▶
Only clean the axial piston unit with a damp cloth; cleaning with a dry cloth could
cause static electricity to build.
▶
Remove major external contamination and keep clean sensitive and important
components, such as solenoids, valves, indicators and sensors.
RE 92050-01-X-B1/2019.08.23, Axial piston variable pump A4VSO, Bosch Rexroth AG
Maintenance and repair
DAnGer
55/72