AXIS XPQ1785 Explosion-Protected Camera
The device interface
An ONVIF media profile consists of a set of configurations that you can use to change media stream settings.
Add media profile: Click to add a new ONVIF media profile.
profile_x: Click a profile to edit.
Analytics metadata
Metadata producers
Metadata producers lists the channels used by apps and the metadata they are streaming from the device.
Producer: The app producing the metadata.
Channel: The channel used by the app. Check to enable the metadata stream. Uncheck to disable the stream for compatibility
or resources management reasons.
Detectors
Shock detection
Shock detector: Turn on to generate an alarm if the device is hit by an object or if it is tampered with.
Sensitivity level: Move the slider to adjust the sensitivity level at which the device should generate an alarm. A low value
means that the device only generates an alarm if the hit is powerful. A high value means that the device generates an alarm
even with mild tampering.
Accessories
Washer
Lock nozzle position: First, pan and tilt the camera until the nozzle is in the center of the image. Then, turn on Lock nozzle
position to save the camera position as the washer position. When you turn it on, the washer button appears in the live view.
Each time you click the washer button, the camera moves to the locked position.
Pump time: Set the duration of the wash spray sequence in seconds.
Wiper time: Set the duration of the wiper sequence in seconds.
Pump connection: Select the washer pump pin that the washer is connected to. Go to System > Accessories > I/O ports and
check that the selected pin is configured as an output.