DEVICE DESCRIPTION
2
The permissible ambient temperature range is indicated on the nameplate; depending on the
device version it is
T
= -40...+65°C / -40...+149°F or T
amb
The permissible minimum product temperature is -40°C / -40°F.
Type
DK37/M8E/../..
DK37/M8M/../..
DK37/M8M/../..
DK37/M8M/../..
Table 2-4: Minimum permissible ambient temperature depending on electrical built-ins
2.8 Surface temperature for equipment protection level Db
For use in areas with flammable dust it should be noted that the indicated maximum surface
temperature of T75°C at an ambient temperature of +65°C / +149°F and a product temperature
of +75°C / +167°F is valid without a dust coating.
For higher product temperatures the maximum surface temperature is defined by the product.
2.9 Electrical data
Built-in equipment for the variable area flowmeter may only be connected to separate
intrinsically safe circuits with the following maximum values:
Device version
DK37/M8E/../..
DK37/M8M/../..
SC2-N0...
DK37/M8M/../..
SJ2-SN
DK37/M8M/../..
I7S2002-N
Table 2-5: Maximum values for intrinsically safe circuits
WARNING!
Also, when operating the variable area flowmeter outside of the hazardous area, the connection
must be made to an intrinsically safe circuit.
When connecting to non-intrinsically safe circuits, there is a risk of damage to the safety-
defining components.
12
= -25...+65°C / -13...+149°F.
amb
Electrical built-ins
Signal output 4...20 mA
SC2-N0
I7S2002-N
SJ2-SN
Without electrical built-ins
Maximum values
U
[V]
i
30
16
16
16
www.krohne.com
Min. ambient temperature
-40°C / -40°F
-25°C / -13°F
-40°C / -40°F
-40°C / -40°F
I
[mA]
P
[mW]
i
i
120
1000
25
64
52
169
25
64
52
169
25
64
52
169
03/2019 - 4007510401 - AD DK37/M8 Exi INMETRO R01 en
DK37/M8
C
[nF]
L
[μH]
i
i
0
~ 0
165
150
45
100
165
120