Advertisement
Read the instructions carefully before operating or servicing the dehumidifier.
Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage.
Keep these instructions in a safe place for future reference.
Appliance filled with flammable gas R290.
Before using the appliance, read the owner's manual.
Before installing the appliance, read the installation manual.
Before repairing the appliance, read the service manual.
The Refrigerant R290
Do not try to accelerate the defrosting process or to clean the appliance in different ways other than those recommended by the manufacturer. Should repair be necessary, contact your nearest authorized Argoclima Service Centre. Any repairs carried out by unqualified personnel may be dangerous. The appliance has to be stored in a room that doesn't have any continuously operating ignition sources. (for example: open flames, an operating gas appliance or an operating electric heater.) Do not pierce or burn.
Appliance has to be installed, operated and stored in a room with a floor area larger than 4 m2.
For repairs, strictly follow manufacturer's instructions only for appliances filled with R290 flammable gas. Be aware that refrigerants do not have any odour.
The following space must be maintained to ensure the operating efficiency of the dehumidifier.
Place the product on a flat and stable heat-resistant surface, at least 1 metre away from flammable or heat-sensitive materials and 50 cm away from walls or other obstructions.
Make sure the water tank is in the correct position.
Connect the power cord to a suitable electric socket (220-240V/50Hz).
Turn the appliance on with ON/OFF on the control panel.
The dehumidifier is designed to operate at ambient temperatures from + 5°C to + 32°C.
If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.
When this happens the dehumidifier goes into defrost mode and the defrost LED comes on. The compressor stops, but the fan continues running.
The defrosting operation may start up and operate for some minutes; during the defrosting operation, the dehumidification function may intermit: please don't turn off the switch or pull out the power plug of the dehumidifier.
We recommend not using the dehumidifier in room temperatures lower than 5°C.
The appliance will only start operating if the humidity level in the room is above the set value.
The dehumidifier will continue to operate until the set humidity level has been reached, with the exception of interruptions caused by a full tank. In this case, empty and reinstall the tank: the dehumidifier will now start running again.
After each interruption of its operation, at least 3 minutes must pass before the dehumidifier starts up again: this delay prevents the compressor being damaged.
If, on the other hand, the set humidity percentage is higher than the level currently found in the room, the dehumidifier will not start.
If you follow the start up instructions but the dehumidifier does not start stops for no reason, make sure the plug and power cord are in good working order. After doing so, wait for 10 minutes and then restart the appliance.
If the dehumidifier still does not start after 10 minutes, or if either the power cord or plug are damaged, switch off the appliance and contact an after-sales service centre.
When the dehumidifier is running, the compressor produces heat and the appliance emits warm air into the room. The room temperature will therefore tend to increase. This is completely normal.
To turn the dehumidifier off press the ON/OFF button. This shuts off power to the unit.
Unplug the appliance if you do not intend to use it for some time.
The water extracted from the air can be collected in the provided front tank.
When the tank is full, the unit turns off. The FULL TANK led turns on and the unit beeps for about 20 seconds. Empty the tank. Use two hands to empty the tank.
To switch off the appliance, press the ON/OFF button and wait a few seconds.
N.B.
Do not use the drain hose when you are collecting condensation in the tank, otherwise water can leak out of the hose.
You can fit a 17 mm internal diameter PVC hose, a 19 mm outer diameter and a 30cm length hose to drain the tank continuous (included).
Turn off the appliance and remove the plug before connecting the hose.
Remove the drain hole cap and connect a PVC hose (supplied) to the drain hole.
Connect the hose to water drain.
The height of the drainage hose must not exceed that of the hole: do not block the drainage hose exit.
Occasionally check that the adapter and drainage hose are tightly connected and not damaged or blocked.
DISPLAY
Shows the relative humidity setting.
TIMER LED
Shows the timer setting.
TANK FULL LED
When the tank is full, the TANK FULL LED lights on and the dehumidifier stops running. A 10 second beep sounds. Remove the tank and empty it (as indicated in "HOW TO ELIMINATE CONDENSATION"), then restore it; the dehumidifier will start running again.
When the tank is not correctly positioned, the unit will sound a beep lasting approximately 10": then the LED will turn on.
Reposition the tank correctly.
DEFROST LED
The dehumidifier is designed to operate at ambient temperatures from + 5°C to + 32°C.
If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.
When this happens the dehumidifier goes into defrost mode and the defrost LED lights on. The compressor stops, but the fan continues running.
We recommend not using the dehumidifier in room temperatures lower than 5°C.
CHILD LOCK LED
To disable the buttons, press the "+" and "-" buttons for 3 seconds: the LC symbol will appear on the display and the unit will sound a beep. To reactivate the control panel, press the "+" and "-" buttons again for 3 seconds.
FAN SPEED LED
Shows the fan speed: HIGH or LOW.
OPERATION LED
You can select one of the following dehumidification modes: the corresponding LED will turn on.
MODE | COMPRESSOR | FAN SPEED | DEFROST | TIMER | TANK FULL ALARM | HUMIDITY SETTING |
Fan | NO | Adjustable | NO | YES | YES | NO |
Dehumidify | YES | Adjustable | YES | YES | YES | YES |
Automatic | YES | Adjustable | YES | YES | YES | NO |
Continuous | YES | Low | YES | YES | YES | NO |
Fast Dry clothes | YES | High | YES | YES | YES | NO |
LED COLOR:
The front LED under the control panel changes colour in according to the humidity level in the room:
AUTO RESTART: the dehumidifier starts up again after a power failure.
Always pull the dehumidifier's plug out of the power socket before cleaning it, to prevent electric shock and malfunction.
Do not wet the appliance or immerse it in water, otherwise electric shocks may occur.
Use a damp and soft cloth to clean the exterior surface of the dehumidifier.
Do not use solvents, petrol, xylene, talcum powder or brushes to clean the unit: these may damage the surface or colour of the casing.
We advise removing the tank once every few weeks to prevent mould and bacteria forming on it. Fill the tank with clean water a small amount of detergent; swill the water around in it, then it out and rinse it thoroughly.
The filter is designed to remove dust or dirt from the air.
If the filter is clogged by dust, electricity consumption will be higher than normal.
Cleaning instructions:
Do not use the dehumidifier without the filter as dust may affect the efficiency of the evaporator, resulting in higher energy consumption.
PROBLEM | POTENTIAL CAUSE | SOLUTION |
The dehumidifier is not working. It is not possible to adjust the settings. | The temperature is above 32°C or below 5°C. The internal tank is full. The tank is not positioned correctly. The set humidity level is higher than that in the room. | Empty the tank Position the tank correctly |
The noise suddenly increases while running | The compressor has just started. There is a power connection problem. The unit is placed on an uneven surface. | |
Condensation is not collected in the tank | The room is too big for the unit's capacity. The doors are open. There are other devices producing moisture in the room. | |
Reduced dehumidification effect | The room temperature is too low. The set humidity level is inadequate. The filter is full of dust. The doors and windows are open. If the unit is running with a temperature between 5 and 15°C, the unit will pause for automatic defrosting. The compressor will pause for short periods. After the defrost, the unit will resume normal operation. | Reduce the humidity level. Clean the filter. Close any doors and windows. |
At first, the air might have a musty smell | Due to the temperature difference of the heat exchanger, the air might have a strange smell at first. | |
There is water in the tank even when using the hose for continuous condensation drainage | Check the drainage connections. The drainage hose is not connected properly. | Connect the hose correctly. Remove the drainage hose and replace it. |
The ON/OFF LED does not turn on when the power is connected | There is no power or the plug is not inserted correctly. | Check the electrical power supply. Make sure that the electric circuit and plug are not damaged. Make sure that the cable is not damaged. |
The dehumidifier stops working during dehumidifying process. | Whether the room temperature is too high or too low and out of the working scope of the dehumidifier. | The dehumidifier may start automatically when the room temperature returns to the working scope. |
The clothing can't be dry fast. | Whether the room temperature is very low. | The wet clothing may dry more slowly in low temperature. |
The dehumidifier stops intermittently during the operation. | The defrosting. | |
The humidity of the room can't reduce. | The room area is too big, which is over its application scope. The door and windows of the room aren't closed. The machine unit is operated with a kerosene heater which releases steam. | |
Unpleasant smell. | The smell may come from the wall, furniture and other things. | |
The machine unit makes a sound during operation. | The sound made by the flowing of the refrigerant may eliminate or lower automatically while the system operates stably. | |
There is water in the tank. | Since each machine unit has taken operation test before leaving the factory, some water remains on the evaporator flows to the water tank. | |
The FULL indicator led is on. | When the water tank is full, the FULL indicator led is on for reminding. |
LILIUM EVO 11
The unit contains R290, a natural greenhouse gas with global warming potential (GWP) = 3 - Kg. 0.035 = 0.000105 Tons CO2 equiv.
Do not release R290 into the atmosphere.
LILIUM EVO 13
The unit contains R290, a natural greenhouse gas with global warming potential (GWP) = 3 - Kg. 0.045 = 0.000135 Tons CO2 equiv.
Do not release R290 into the atmosphere.
This appliance may not be scrapped with domestic waste at the end of its life cycle. We call your attention to the crucial role played by the consumer in the re-use, recycling and other forms of recovery of such waste.
The appliance must be scrapped by a sorted waste disposal centre or by returning it to the retailer (no charge is levied for this service), when you purchase a new equivalent appliance.
Sorted disposal of electric and electronic equipment prevents the negative effects on the environment and human health resulting from improper scrapping, and also allows the materials from which it is made to be recovered and recycled, with significant savings in terms of energy and resources.
The sorted disposal requirement is indicated by the crossed waste bin label affixed to the appliance.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Argo LILIUM EVO 11, LILIUM EVO 13 - Dehumidifier Manual
Advertisement
Need help?
Do you have a question about the LILIUM EVO 11 and is the answer not in the manual?
Questions and answers