Page 1
DEHUMIDIFIER OPERATING INSTRUCTIONS Read the instructions carefully before operating or servicing the dehumidifier. Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage. Keep these instructions in a safe place for future reference. V 10/16...
Page 2
GENERAL OPERATING AND SAFETY INSTRUCTIONS This appliance is a highly efficient dehumidifier, designed for domestic use only! Use this dehumidifier only as outlined in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or malfunctions. ...
Page 3
can cause fires or electric shocks. If the power cord is damaged, it must be replaced by a service centre. Do not place heavy objects on top of the appliance. To prevent water spills, empty the water tank before moving the appliance.
DESCRIPTION OF PARTS FRONT VIEW CONTROL PANEL DEHUMIDIFIED AIR OUTLET CONTINUOUS CONDENSATION DRAINAGE HOLE COVER AIR INTAKE REAR VIEW POWER CORD ATTACHMENT HOLE CONDENSATION COLLECTION TANK POWER CORD CHECKS BEFORE START UP Check that the float and the condensation collection tank are correctly positioned Remove the tank using both hands and following the direction of the arrow.
Check the position of the float inside the tank; it may have shifted during the move. If it is not positioned correctly, reposition it before using it. Float Incorrect Correct position position Then, reposition the tank. OPERATING INSTRUCTIONS APPLIANCE START-UP Place the product on a flat and stable heat-resistant surface, at least 1 metre away from flammable or heat-sensitive materials and 50 cm away from walls or other obstructions.
Page 6
REMOVING THE CONDENSATION - FILLING THE INNER TANK The water extracted from the air can be collected in the rear tank. When the tank is full, the unit turns off. The FULL TANK led turns on and the unit beeps for about 10 seconds. To switch off the appliance, press the ON/OFF button and wait a few seconds.
CONTROL PANEL DEHUMIDIFICATION HIGH-MEDIUM-LOW TIMER LED TANK FULL LED MODE LED DEFLECTOR FAN SPEED LED DISPLAY POSITION LED FILTER RESET AIR FLOW DEHUMIDIFICATION ON/OFF HUMIDITY TIMER DIRECTION MODE SELECTION: BUTTON SETTING SETTING - SMART - CONTINUOUS - QUIET BUTTONS - DRY (1) ON/OFF BUTTON: press to turn the dehumidifier on and off.
We recommend removing the tank once every few weeks to prevent mould and bacteria from forming. Fill the tank with clean water a small amount of detergent; swill the water around in it, then it out and rinse it thoroughly. PLATINUM 21 Remove the tank and pour out any remaining water.
CLEANING THE AIR FILTER The filter is designed to remove dust or dirt from the air. If the filter is clogged by dust, electricity consumption will be higher than normal. To optimise humidity removal efficiency, clean the filter when the FILTER CLEAN LED turns on.
Page 10
TROUBLESHOOTING PROBLEM POTENTIAL CAUSE SOLUTION The dehumidifier is not working. The temperature is above 35 ° C or below 5 It is not possible to adjust the settings. °C. The internal tank is full. Empty the tank The tank is not positioned correctly. Position the tank correctly The set humidity level is higher than that in the room.
Page 11
REGULATION (EU) No. 517/2014 - F-GAS PLATINUM 21 The unit contains R134A, a fluorinated greenhouse gas with global warming potential (GWP) = 1430 - Kg. 0.185 = 0.265 Tons CO equiv. Do not release R-134a into the atmosphere. PLATINUM 41 The unit contains R410A, a fluorinated greenhouse gas with global warming potential (GWP) = 2087.5 - Kg.