Instructions for use Mobilizer Ottfried Table of contents Information on the instructions for use foreword and general information ....3 Version: Copyright............4 Date of issue: 02.05.2023 Disclaimer............4 Language: English Definition of groups of persons ......5 Description and purpose ........6...
Thank you for choosing a product from Reha & Medi Hoffmann GmbH. These instructions for use provide you with all the important information and notes on the Mobilizer Ottfried. It is also intended to make it easier for you to get to know the product and to provide instruc- tions for its proper use and safe operation.
Instructions for use Mobilizer Ottfried 1.1 Copyright These operating instructions, including all their parts and illustrations, are protected by co- pyright. The rights to translation, reprinting, extraction of pictorial representations as well as reproduction and storage in data processing systems are reserved, even if only excerpts are used.
Operator is any natural or legal person responsible for the operation of the healthcare facility in which The Mobilizer Ottfried is applied by its employees. User is medical and nursing staff who use the product for mobilisation after instruction by the operator.
Instructions for use Mobilizer Ottfried 2. Description and purpose The Mobilizer Ottfried is a universal therapy device for performing patient mobilisation from a lying to a sitting position. The sitting/lying surface is mounted on a compact chassis with four swivelling castors and is easy to manoeuvre.
• The patient's body weight must not exceed 250 kg. The Mobilizer Ottfried must not be used if a patient has failed the examination of a profes- sional with medical competence.
Instructions for use Mobilizer Ottfried 3. Permissible operating conditions/place of use The Mobilizer Ottfried is intended for indoor use. If it is necessary to negotiate steps or thresholds, these must be sloped or a ramp must be created. The ramps or an inclined plane may have a maximum gradient of seven degrees.
The Mobilizer Ottfried has been designed and produced in accordance with the state of the art and its recognised safety rules. Nevertheless, risks of injury to staff, patients and third parties or damage to the Mobilizer Ottfried or other property cannot be ruled out if the Mo- bilizer Ottfried: •...
Page 10
ATTENTION! Mobilizer Ottfried is not suitable as a climbing aid, nor is it permitted to sit down on the backrest or foot end. An impermissible load can cause the Mobi- lizer Ottfried to tip over.
• The operator must ensure that the person on the Mobilizer Ottfried is suitably secured against falling out. • The operator must ensure that no one can manipulate the Mobilizer Ottfried or be injured by moving parts during adjustment. The patient's arms should be in the patient's lap or on the armrests.
Instructions for use Mobilizer Ottfried 5.4 Products with battery Products with rechargeable batteries may only be operated with the rechargeable batteries supplied or other rechargeable batteries approved by the manufacturer. The rechargeable bat- teries may only be charged in the charging station provided, including the mains adapter.
Fig. 5: Backrest adjustment 8. Tilt adjustment The Mobilizer Ottfried has a seat tilt adjustment. This can be adjusted independently of the seat height and back- rest angle. The seat and reclining surface can be tilted up to 9°...
Instructions for use Mobilizer Ottfried 9. Hand control The tilt of the backrest and seat, the adjustment of the seat height, as well as the operation of the lower leg length (height of the foot step) is carried out by means of two electric motors.
To get out forward, the seat of Mobilizer Ottfried is tilted forward as far as it will go and the footrest is stowed under the calf pad. In this position, an attendant can help the patient out of Mobilizer Ottfried with minimal effort while observing kinaesthetic principles.
Instructions for use Mobilizer Ottfried 12. Armrests The armrests provide support for the patient without limiting the seat width. They lower automatically to the level of the seat cushion when adjusted to the couch, facilitating the prone lateral transfer of patients. For seated...
The battery is inserted into the charging station in the same way as on the battery holder on the Mobilizer Ottfried (see Fig. 17). Please also observe the general safety instruc- tions (chapter 5). Preferably, the charging station should be mounted vertically on a wall (see Fig.
Download 18. Re-use The Mobilizer Ottfried can be reused indefinitely within its product life. For reuse, the usabi- lity must be checked in accordance with point 5.3 and reprocessing must be carried out thoroughly in accordance with point 18. If there are any irregularities, especially in point 5.3, a comprehensive safety check (STK) is necessary.
Instructions for use Mobilizer Ottfried 19. Equipment options neck cushion Fixing headrest Table with upholstery Chest strap Positioning cushion Chest strap Positioning cushion calf belt Leg strap Lap belt Fig. 19: Recommended equipment 19.1 Headrest, fixing This headrest is fitted in place of the standard neck pad and has an additional strap to se- cure the head over the patient's forehead (see Fig.
Pressing the bar in the direction of the arrow releases the lock. The side bars are fitted at the factory, cannot be retrofitted and cannot be com- bined with push handles. Pads for the side bars are additionally availa- ble. Fig.
Instructions for use Mobilizer Ottfried 20. Warranty The warranty period for the Mobilizer Ottfried including the additional equipment is 24 months from the date of delivery. Excluded from warranty claims are: • Wear parts (e.g. armrest pads, locking screws) • Damage due to non-observance of these instructions for use •...
Total product IPX4 +5°C to +40°C +5°C to +40°C Mobilizer Ottfried No temperature restrictions Spiral cable: 1.3 m; Hand control IP67 maximum plug-in 2.5 m SCU-Control IPX4 +5°C to +40°C +5°C to +40°C...
Fig. 24: The type plate is located on the back of the backrest at the height of the push handle. Reha & Medi Hoffmann GmbH Debyestraße 5 ● 04329 Leipzig • Germany Tel: +49 341 39284960 ● Web: www.rehamedi.de ® Mobilizer Ottfried 12231010 +40°...