For all jobs which are to be carried out on an installed valve, the works safety require-
ments and the gerneral accident prevention instructions must be observed. Moreover,
the general installation and maintenance instructions for atomac fluorcarbon resin lined
valves must be considered.
1.
Prior to disassembly, the valve must be cleared of all fluid according to the
above-mentioned instructions. Particular care must be taken that during rin
sing and draining of the piping, the valve is opened and closed repeatedly.
These cycles (opening and closing) are to be
repeated during draining of the piping. Only when following this procedure, is it
ensured that all remaining pressure inside the body (stem guide and ball seats) is
eliminated.
2.
For disassembly of the valve, put body on a work bench with a soft cover (rubber
A
mat). If necessary, remove the stops (310). Remove hexagon bolt (110)
and lock washer (150) and grounding device
(170).
300
304
310
3.
Open valve completely. Remove hand lever
(300).
4.
Disassemble gland follower (060) and gland
insert (065). If necessary, stud bolts
(120) can also be removed now.
5.
Remove body bolts (080) and separate side
piece from body.
6.
Remove first ball seat ring (030).
7.
Put ball in closed position and push ball
out of the body.
Remove stem (040) by pushing it down
8.
through the body (010). Care must be taken
not to damage body liner.
A
Chevron packing (100) can easily be
9.
removed.
B
B
Technical Manual
020
AKH6 - atomac vessel bottom drain valve
510
Register:
Page:
Date:
Revision:
304
300
110
170
060
065
100
120
040
050
030
080
6
9
07.1991
06.2020
150
310
010
090

Advertisement

Table of Contents
loading

Table of Contents