2-1. Overview of Control Buttons

Remote
Picture Off/
Sensor
Timer indicator

2-2. LED Display Specification

LED Typ e
D escription
POWER
Green: LED
ST ANDB
Y
Red: One LE D
Timer
Or a nge
: One LED

2-3. LED Display Control

Display
Status
Power LE D
POWER ON
Green lights
OF
F
ST ANDBY
Failure
OFF

SELF DIAGNOSTIC FUNCTION

Power
PROG
Programme
Volume
Input select/
Enter
Menu
Standby
Power
indicator
indicator
Remark
Gr e en lights at po wer ON.
Red lights during standby .
Or a nge lights
during Timer ac tivation.
Remark
Standby LED
Microcomputer is
OFF
in a normal stat e.
Microcomputer is
R ed lights
in a sleep stat e.
Classify the tr ouble
Red flashes
causes b y the no.
of red blinking.
KLV-26,32 NX400(S/B), 26,32 NX400(S/B)/S, 32,40 NX500
SECTION 2

2-4. LED Pattern

When safety shutdown occurs, Standby LED display reports the
cause by using the lightning patterns as indicated below.
3.0 sec
0.5 sec
0.5 sec
Example:
The figure above shows LED display when
SHUTDOWN is caused by Balancer Error. It repeats
flashing for a specified number of times in 0.5sec/
cycle and has a 3 seconds interval of lighting off.
Please note that a 3 seconds interval of lighting off
is fixed regardless of abnormal state types.
– 5 –
3.0 sec
RM-GA018