Download Print this page

KeLi XK3118K9 Calibration Manual page 2

Weighing indicator

Advertisement

Press 【 1】
8
【Input】
Press 【 1】
9
【Input】
Press 【 0】
10
【Input】
Press 【 2】
11
【Input】
12 Press【0】 【0】 【1】 【1】
13
Press【Input】
14
Press【Input】
15
Note 1: in step 6 and step 7, if press 【Weigh】, it means this step does not work, it enters to the next step directly
Note 2: in the calibration process, press 【Weigh】in other steps, it will return back to weighing status
Note 3: Pn parameter setting ways
Input value
W: Stability range
X: zero tracing range
Y:
manual
zero-setting
range
Z:
Start-up
zero-setting
range
IV. Operation of Parameters Calibrated
No.
Function
Inquire the recent
1
date of calibration
Backup the
2
calibration
parameters
Recover the
3
calibration
parameters
Inquire the date to
backup the
4
calibration
parameters
V. Timing shut-down and random unlock
Press 【PRINT SET】 under weighing status. Input password 【88】 . Then press 【INPUT】 . The indicator displays
【SECU 0】 , which means that enters timing shut-down setting menu (the password and date of timing shut-down can
be changed). The password of timing shut-down should be kept carefully. The factory setting password is
Press【Input】to confirm after the stability symbol light becomes bright
Press
Communication address ( 01~26 )
【Adr 01】
Press
Serial communication baud rate ( 0~4 ), respectively corresponds to
【bt
1】
baud rate: 600/1200/2400/4800/9600 bps (factory default setting: 1)
Serial communication mode: 0—continuous sending, 1—command
Press
【tF
0】
response (factory default setting: 0)
Filter strength (0~6): 0: weakest, 6: strongest (factory default
Press
【Flt
2】
setting: 2)
Special parameter setting (factory default setting: 0011)
X: 0 Power saving mode OFF
X: 0 weight unit is kg;
【Y
XYZ】
Y: 0 data record not use cargo number;
【Y
011】
number
Z: 0 data record not use vehicle number; 1 data record use vehicle
number
Three section division displays lower limit, the division value will
switch downwards to next part when the gross weight is less than this
【L
0】
value, if calibration division value is 1, it will not switch (factory
default setting: 0)
Three section division displays upper limit, the division value will
switch upwards to the next part when the gross weight is more than this
【H030090】
value, if calibration division value is 100, it will not switch (factory
default setting: division value switch not valid)
【 20000 】 Calibration finishes, return back to weighing status
0
1
2
0.5
1.0
1.5
0
0.5
1.0
0
2%
4%
0
2%
4%
Press 【SET PRINT】 , input 【9】 【 0】 → Press 【 Input】 to display"d**.**.**"(Date)→Press
【Input】to display "t**.**.**"(Time)→Press【Input】to return to weighing status.
Press the touch button (the beep sounds and calibration lamp fashes) → Press 【SET
PRINT】 and input 【9】 【1】 → Press 【 Input】 to display "blbc 0"→ Input 【 1】 (any number
except zero)→ Press 【Input】 to backup the calbiration parameters, and return to weighing
status.
Press touch calibration switch (the beep sounds and calibration lamp fashes)→Press 【 SET
PRINT】 and enter 【9】 【2】 →Press 【 Input】 to display"blHF 0"→Enter 【 1】 ( any number
except zero )→Press 【 Input】 to recover the calibration parameters, and return to weighing
status. The recovery of the calibration parameters is deemed as one complete calibration.
Press 【 SET PRINT 】
display"d**.**.**"(Date)→Press【Input】to display "t**.**.**"(Time)→Press【Input】
to return to weighing status.
3
4
5
2.0
2.5
3.0
1.5
2.0
2.5
10%
20%
No
limit
10%
20%
No
limit
Operation
and input 【 9 】【 3 】 →Press 【 Input 】 to
(factory default setting: 1)
1 Power saving mode ON
1 weight unit is ton
1 data record use cargo
6
7
8
3.5
4.0
4.5
3.0
3.5
4.0
——
——
——
——
——
——
——
——
9
Unit
5.0
uV
4.5
E
F.S
F.S

Advertisement

loading