Intended Use; Product Without Special Function; Product With Special Function Z - GEM 4232 Operating Instructions Manual

Travel sensor for linear actuators
Table of Contents

Advertisement

Available languages

Available languages

4 Intended use

Please note:
This is a retrofit kit only. Different items are required for spare
parts supply and new requirements. This needs to be ob-
served for reordering at a later date in particular.
Instead of the item information specified, use the following
item:
887540
4232000Z140
Travel
57
3005M00000
sensor for
Z
linear actu-
ators
4 Intended use
Danger of explosion
▶ Danger of death or severe injury.
Only use the product in potentially ex-
plosive zones confirmed in the declara-
tion of conformity.
Improper use of the product
▶ Risk of severe injury or death.
▶ Manufacturer liability and guarantee will be void.
Only use the product in accordance with the operating
conditions specified in the contract documentation and in
this document.
The product GEMÜ 4232 is designed for fitting to a GEMÜ
valve in order to detect the position of linear actuators elec-
trically. The product works as an analogue travel sensor sys-
tem based on a resistance value (potentiometer) that
changes linearly with the stroke position. The product is posit-
ively connected with the actuator spindle by means of a
GEMÜ 4232
5 m cable,
0–30 mm
open cable
ALU ATEX
ends
Ex eC;nC;tC
DANGER
WARNING
mounting kit (spring, operating bush). The measurement sig-
nals (resistance value) can be checked using the electrical
connections.

4.1 Product without special function

The product is not intended for use in potentially explosive
areas.

4.2 Product with special function Z

The product with the special version Z order option is inten-
ded for use in potentially explosive areas of zone 2 with
gases, mists or vapours and zone 22 with combustible dusts
in accordance with EU Directive 2014/34/EU (ATEX).
The product has the following explosion protection marking:
ATEX
Gas:
II 3G Ex ec nC IIC T4 Gc X
Dust:
II 3D Ex tc IIIC T80°C Dc X
EN IEC 60079-0:2018
EN IEC 60079-7:2015/A1:2018
EN IEC 60079-15:2019
EN 60079-31:2014
IECEx
Gas: Ex ec nC IIC T4 Gc X
Dust: Ex tc IIIC T80 °C Dc X
Certificate: IECEx IBE 20.0027 X
The product has been developed in compliance with the fol-
lowing harmonised standards:
IEC 60079-0: 2017 (edition 7)
IEC 60079-7: 2017 (edition 5.1)
IEC 60079-15: 2017 (edition 5)
IEC 60079-31: 2013 (edition 2)
Use of the product is permissible in the following ambient
temperature ranges: -10 °C to +70 °C
The explosion-protected design is marked with index Z.
For use in potentially explosive areas, the following conditions
or operation limits must be observed:
Special conditions for use:
The housing must be installed protected from mechanical
influences.
Connection cables and connectors must be protected from
damage.
RFID chips must not be read out in potentially explosive areas.
20 / 32