Crown Xavier X-4KW-M User Manual page 24

Hybrid inverter
Table of Contents

Advertisement

31
Battery equalization voltage
33
Battery equalized time
34
Battery equalized timeout
35
Equalization interval
Equalization activated
36
immediately
Reset all stored data for PV
37
generated
power
output load energy
If "Flooded" or "User-Defined" is selected in program 05, this
program can be set up.
default: 29.2V
60min (default)
120min (default)
30days (default)
Enable
If equalization function is enabled in program 30, this program can
be set up. If "Enable" is selected in this program, it's to activate
battery equalization immediately and LCD main page will show
"
". If "Disable" is selected, it will cancel equalization function
until next activated equalization time arrives based on program 35
setting. At this time, "
Not reset(Default)
and
22
Setting range is from 25.0V to
31.5V for 3.6K model and 48.0V to
62.0V for 7.8K model. Increment of
each click is 0.1V.
Setting range is from 5min to
900min. Increment of each click is
5min.
Setting range is from 5min to 900
min. Increment of each click is 5
min.
Setting range is from 0 to 90 days.
Increment of each click is 1 day
Disable (default)
" will not be shown in LCD main page.
Reset