1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1

1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2 Terminal description (see Fig. 1) . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8
8.1 Wiring example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.2 Internal wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.3 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1 About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety-monitoring module. The
operating instructions must be available in a legible condition and a
complete version in the vicinity of the device.
1.2 Target group: authorised qualiied personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical speciications for the
selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the proper functionality of the entire machinery or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating instruc-
tions manual, the country-speciic installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Elan
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability. Subject to technical modiications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
1.6 Warning about misuse
In case of inadequate or improper use or manipulations of
the safety-monitoring module, personal hazards or damage
to machinery or plant components cannot be excluded. The
relevant requirements of the standard EN 1088 must be
observed.
EN
SRB 401EM-115V / -230V
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB 401EM-115V and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal SRB 401EM-115V

  • Page 1 Operating instructions Safety-monitoring module SRB 401EM-115V / -230V 1 About this document 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety-monitoring module. The operating instructions must be available in a legible condition and a complete version in the vicinity of the device.
  • Page 2 Operating instructions Safety-monitoring module SRB 401EM-115V / -230V 2.4 Technical data 1.7 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from General data: defective mounting or failure to comply with this operating instructions IEC/EN 60204-1, EN 60947-5-1;...
  • Page 3 Operating instructions Safety-monitoring module SRB 401EM-115V / -230V 2.5 Safety classiication 5 Operating principle and settings Standards: EN ISO 13849-1, IEC 61508, 5.1 LED functions EN 60947-5-1 • K1/K2: status channels 1 and 2 Stop 0: up to e Control category: Stop 0: up to 4 5.2 Terminal description (see Fig.
  • Page 4 Operating instructions Safety-monitoring module SRB 401EM-115V / -230V 7 Disassembly and disposal 7.1 Disassembly The safety-monitoring module must be disassembled in a de-energised condition only. 7.2 Disposal The safety-monitoring module must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations.
  • Page 5 Appendix X, Alboinstraße 56 2006/42/EC: 12103 Berlin ID n°: 0035 Place and date of issue: Wuppertal, October 6, 2009 Authorised signature Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net.
  • Page 6 Elan Schaltelemente GmbH & Co. KG Im Ostpark 2, D - 35435 Wettenberg Postfach 1109, D - 35429 Wettenberg Telefon: +49 (0)641 9848-0 Telefax: +49 (0)641 9848-420 E-Mail: info-elan@schmersal.com Internet: www.elan.de...

This manual is also suitable for:

Srb 401em-230v

Table of Contents