Husqvarna TC 112 Operator's Manual page 27

Hide thumbs Also See for TC 112:
Table of Contents

Advertisement

Available languages

Available languages

that is used for the emergency start must also have a 12
V system with negative ground.
To connect the jumper cables
WARNING:
of explosive gas that comes from the
battery. Do not connect the negative
terminal of the charged battery to or near the
negative terminal of the weak battery.
CAUTION:
your product to start other vehicles.
1. Connect one end of the red battery cable to the
POSITIVE (+) terminal (A) on the start relay below
the seat.
B
2. Connect the other end of the red battery cable to the
POSITIVE (+) battery terminal (B) on the charged
battery.
WARNING:
the red battery cable touch the chassis.
This will cause a short circuit.
3. Connect one end of the black battery cable to the
NEGATIVE (-) battery terminal (C) on the charged
battery.
4. Connect the other end of the black battery cable to
a CHASSIS GROUND (D), away from the fuel tank
and the battery.
To remove the jumper cables
Note:
Remove the jumper cables in the opposite
sequence to how you connect them.
1. Remove the BLACK cable from the chassis.
2. Remove the BLACK cable from the fully charged
battery.
3. Remove the RED cable from the 2 batteries.
1903 - 002 - 06.02.2023
Risk of explosion because
Do not use the battery of
C
A
D
Do not let the ends of
To replace the battery
WARNING:
burn injuries. Do not use metal wristbands
or other metal accessories. Metal items that
touch the battery terminals can cause burn
injuries, electrical shock, and short circuit of
the battery.
1. Remove the strap and the battery cover.
Note:
The position of the battery is at the left rear
wheel.
2. Remove the terminal cover on the black battery
cable.
3. Remove the screw, the nut, and the black battery
cable from the negative (-) terminal on the battery.
4. Remove the terminal cover on the red battery cable.
5. Remove the screw, the nut, and the red battery
cable from the positive (+) terminal on the battery.
6. Carefully remove the battery from the product.
7. Put a new battery in position.
8. Attach the red battery cable to the positive (+)
terminal on the battery and install the nut and the
screw.
9. Install the terminal cover on the red battery cable.
Risk of electrical shock and
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc 114970 62 23-01970 62 22-01

Table of Contents