Wow COOLIUS 2700 BT Operator's Manual

Automotive air-conditioning service equipment

Advertisement

Quick Links

OPERATOR MANUAL
Automotive Air-Conditioning Service Equipment
WOW! COOLIUS 2700 BT
2117_ENG / Version:10/03/2011

Advertisement

Table of Contents
loading

Summary of Contents for Wow COOLIUS 2700 BT

  • Page 1 OPERATOR MANUAL Automotive Air-Conditioning Service Equipment WOW! COOLIUS 2700 BT 2117_ENG / Version:10/03/2011...
  • Page 2 WOW! Coolius 2700BT This equipment has been extensively researched, designed and developed with the prime objective in satisfying the workshop operator and technician in carrying out the most efficient air-conditioning diagnostic and service procedure, which can not be achieved with any other equipment of this kind.
  • Page 3: Table Of Contents

    WOW! Coolius 2700BT Contents Introduction ............................ 4 SAFETY FIRST! Important Safety Information's ..................5 Technical Features ........................... 6 Preparing the Machine for Use ......................7 Main Components Location ......................8 Switching ON the Machine ......................10 Icons and their meaning ........................ 11 Printer Set Up ..........................
  • Page 4: Introduction

    WOW! Coolius 2700BT Introduction Coolius 2700 BT - Advanced Refrigerant Processor is a user-friendly tool specifically designed for the automotive air-conditioning technicians, to carry out the following functions: Testing air-conditioning system. Recover and recycling the refrigerant from air-conditioning system. Electronically gauge amount of refrigerant recovered from air-conditioning system.
  • Page 5: Safety First! Important Safety Information's

    Maintenance of the unit must only be performed by an authorized technician. Only non aggressive substances to be used for cleaning of the unit. WOW! Coolius 2700-BT does not contain or should be operated with flammable refrigerants. - 5 -...
  • Page 6: Technical Features

    WOW! Coolius 2700BT Technical Features Refrigerant ..............R134a Electronic refrigerant scale ..........5g resolution Load cell ................. 60kg with 150% overload capacity LP and HP gauges ............High Clarity Digital Display Recovery cylinder ............. 27kg Recovery pump ..............Danfoss SC12G, Recovery rate ..............
  • Page 7: Preparing The Machine For Use

    WOW! Coolius 2700BT Preparing the Machine for Use Perform the following steps to prepare the unit before the first use. 1. Remove the carton box and Styrofoam inserts. 2. Check to ensure that all of the accessory components are with the unit:...
  • Page 8: Main Components Location

    Main Components Location NOTE: No hand valves are incorporated on the Coolius 2700 BT. A series of electronically controlled valves are incorporated to precisely control the functionality of the machine. No more confusion on which valve to turn off or on.
  • Page 9 WOW! Coolius 2700BT 9. New Oil 2 / UV dye Injection vessel - A large capacity vessel of 240ml is mounted on the right side of the unit to electronically inject the oil or UV dye in to the A/C system.
  • Page 10: Switching On The Machine

    WOW! Coolius 2700BT Switching ON the Machine Switch on machine power switch, the machine will display the number of hours left before the maintenance service is required. Followed by self purge and hose evacuation (if necessary). This special function will prevent non- condensable (air) to be pushed in to the cylinder, therefore maintaining maximum refrigerant purity.
  • Page 11: Icons And Their Meaning

    WOW! Coolius 2700BT Icons and their meaning The machine is self purging. Machine requires servicing. Updating software. Set up, adjusting settings. Set weight. Please wait. Edit. Return, returning to previous menu. Left arrow, scrolling left. Right arrow, scrolling right. Up arrow, scrolling up.
  • Page 12 WOW! Coolius 2700BT Power. Start button, starting a function. The air-conditioning system There is no refrigerant in the air- contains refrigerant conditioning system or quick (pressure in A/C system). couplers not open. Recovering (removing) the Recover, yes or no. refrigerant from the air- conditioning system.
  • Page 13 WOW! Coolius 2700BT Oil vessel # 2, injecting oil into Oil vessel # 3 (optional), injecting air-conditioning system. oil in to air-conditioning system. Dye injection vessel (optional), Injecting oil in to air-conditioning injecting dye in to air- system. conditioning system.
  • Page 14: Printer Set Up

    WOW! Coolius 2700BT Printer Set Up The printer is equipped with two keys and green led: >> Paper feed II on line / off line The green led shows the state of the printer: Led constantly ON - Printer in line Led blinking - Printer not in line or no paper Led off - Press II.
  • Page 15: Storage Cylinder Filling Procedure (Refrigerant Transfer)

    WOW! Coolius 2700BT Storage Cylinder Filling Procedure (Refrigerant Transfer) The purpose of the Refrigerant Transfer mode is to transfer new refrigerant from a storage cylinder to the machine cylinder. The machine refrigerant cylinder which is situated behind the cylinder cover is supplied empty of refrigerant.
  • Page 16 WOW! Coolius 2700BT Step 1 - Touch refrigerant recovery icon Step 2 - Touch compressor icon Step 3 - Touch suction (S) icon Step 4 - Touch weight icon Step 6 - Touch confirm icon and press the Start Step 5 - By using the keypad select the desired button on the panel.
  • Page 17: Connecting And Testing The A/C System

    WOW! Coolius 2700BT 10 Connecting and testing the A/C system Use the service hose quick couplers to connect the hoses to the A/C system service ports, bearing in mind that BLUE must be connected to the low-pressure (suction) side and RED to high pressure (discharge) side.
  • Page 18: Recovery & Recycling Mode

    WOW! Coolius 2700BT 11 Recovery & Recycling Mode The purpose of the Recovery & Recycling mode is to recover refrigerant from the air conditioning system, which will condense, purify and store the liquid refrigerant in the storage cylinder ready for re-use.
  • Page 19 WOW! Coolius 2700BT Before recovery process start, the machine will self purge and evacuate the service hoses (if required). During the recovery process the machine will display the amount of refrigerant being recovered. this process can be paused by depressing Stop button and abort the function totally by depressing the Stop button again or restart the process by pressing the Start button.
  • Page 20: Evacuation Mode

    WOW! Coolius 2700BT 12 Evacuation Mode In the evacuation mode the air and moisture in the air conditioning system is removed and exhausted to the atmosphere. The evacuation mode runs for a predetermined time selected by the operator. Step 2 - Touch the Time Icon...