Storage Cylinder Filling Procedure (Refrigerant Transfer) - Wow COOLIUS 2700 BT Operator's Manual

Automotive air-conditioning service equipment
Table of Contents

Advertisement

WOW! Coolius 2700BT
9

Storage Cylinder Filling Procedure (Refrigerant Transfer)

The purpose of the Refrigerant Transfer mode is to transfer new refrigerant from a storage cylinder
to the machine cylinder.
The machine refrigerant cylinder which is situated behind the cylinder cover is supplied empty of refrigerant.
Note: The cylinder is evacuated by the manufacturer.
There are various types of new refrigerant cylinders which are in the market, refillable and disposable
cylinders.
Whenever refrigerant is transferred from either type of cylinder, must always be transferred liquid state in to
the machine.
Using a refillable cylinder to transfer refrigerant (see figure 1 for correct connection
procedure)
Keep the cylinder sitting upright, connect the suction (blue) service hose to new refrigerant cylinder liquid valve
by using the brass adapter provided, open liquid valve on storage cylinder (please note, all cylinder valves are
marked with liquid and vapour on the valve hand wheel), open suction service hose quick coupling >>>
Using a disposable cylinder to transfer refrigerant (see figure 2 for correct
connection procedure)
Connect the suction (blue) service hose to a new refrigerant cylinder valve by using the brass adapter
provided. Turn cylinder upside down for liquid delivery, open the valve on the cylinder, open suction service
hose quick coupling >>>