IQAir Atem X is an air purifier for those who care about the air they breathe. We hope you will enjoy its powerful yet quiet operation, space-saving design and smart functionality as much as we enjoyed designing and manufacturing it for you.
• In case of needing instructions contained damaged. If the power cord is damaged, in electronic format as printed copy you must have it replaced by IQAir, a download from www.iqair.com and print or service center authorized by IQAir, or request at local dealer.
Page 5
• Only use this appliance in conjunction • Never sit or stand on the appliance. Sitting with its intended IQAir accessories and or standing on the appliance may lead to consumables. potential injury and appliance damage.
2. Product overview Atem X has a minimalist, round design. Its air inlet The front of the air purifier is free of functional and outlet are arranged on the circumference of the elements. The control panel is unobtrusively located on air purifier.
Page 7
Product overview Room air is drawn into the air purifier through three air The three air inlet grilles can be removed for cleaning inlet grilles and purified air is delivered through the air and to change the filters. The air outlet grille, which is purifier’s air outlet grille.
Connect to power Atem X can be placed directly against a wall or any other vertical surface, such as a cupboard or beside a Insert the plug into a suitable power socket. Arrange sofa.
Fitting the mobile base Scan the QR code to download the app and start the You can mount your Atem X onto the supplied mobile connection process. The app will guide you through the base. This will allow you to easily move the purifier on steps to connect with your Atem X.
4. The control panel The purifier’s control panel is located on the rear rim, behind the outlet grille. Power button Touch to turn ON, touch again for standby. Smart mode button Touch to toggle between smart mode for automatic fan speed control and the manual fan speed setting.
The control panel Power Touch the power button to turn on your purifier, touch again to switch to standby. When in standby, the purifier can be turned on from the app. All other buttons on the control panel are disabled when the purifier is in standby. Indicator color Power status White...
Fan speed selection Atem X has eight fan speed levels. Tap the control slider to show the current fan speed. Touch again to set the fan speed. The selected speed corresponds to the number of illuminated indicator dots. The indicators revert to display air quality after about 5 seconds.
The control panel Air quality indicator Air quality is displayed as a color on the control panel slider. Indicator color Air quality description Air quality description according to US AQI according to Chinese AQI Green Good Excellent Yellow Moderate Good Orange Unhealthy for Sensitive Groups Lightly polluted...
Wi-Fi Atem X can be connected to a Wi-Fi network to enable remote control via the app. The Wi-Fi button allows you to turn Wi-Fi on and off. To turn off Wi-Fi touch and hold for 2 seconds. The button is also used to connect the purifier to a Wi-Fi network.
Filter status Atem X features smart filters that contain identification and performance parameters and store the filter’s usage history. Atem X calculates the filter’s life as a function of its capacity, the measured real-time airborne pollutant levels and fan speed.
5. Filter replacement Step 1 Step 2 Remove the front cover Remove the three inlet grilles Pull and detach the front cover from the purifier. Open the locking levers. Slide out the inlet grilles to reveal the filters. Carefully set aside the inlet grilles Open the locking levers Detach the front cover Slide out the inlet grilles...
Page 17
Filter replacement Step 3 Step 4 Remove the three used filters Insert the three replacement filters Press the latch towards the filter to unlock and remove Make sure that the filter’s orientation tab is facing the filter. towards the front of the purifier. Do not try to clean and/or reuse the filters.
Page 18
Filter replacement Step 5 Step 6 Replace the inlet grilles Replace the front cover Check that the locking levers are still in the Align the spigot in the center of the front cover with open position. the socket in the fan window. Push the front cover until it snaps into place.
You might need to check and clean the impactors more frequently if you have pets or if you use Atem X in a very dusty environment. Simply look into the inlet grilles. If you see hair and fluff clogging the impactors, they should be cleaned.
7. Technical specifications Input voltage 230 Volt version 220-240 V~ 50-60 Hz 110 Volt version 100-120 V~ 50-60 Hz (Refer to the type label on your device) Power rating Rated power input 110 W Networked standby (Wi-Fi on) < 1.8 W Standby (Wi-Fi off) <...
- consult the dealer or an experienced radio/TV any loose dust from the inlet grilles. technician for help. When not in use, store your Atem X in a clean, dry For Canada: place. Use the original packaging for optimal storage.