  • Page 1 LubriMist® Auto Drain Leg System Installation and Operation Manual Revision 3 9/28/2018...
  • Page 2: Table Of Contents

    Table of Contents I. Manufacturer Contact Information II. Product Description III. Mechanical Operation Conditions IV. Installation V. Typical Installation Diagrams VI. Commissioning VII. Routine Checks VIII. Troubleshooting IX. Drawings and Parts Revision 3 9/28/2018...
  • Page 3: Manufacturer Contact Information

    I. Manufacturer Contact Information This publication provides instruction and information for the LubriMist® Auto Drain Leg System. Design, application and distribution of LubriMist® Oil Mist is covered in other publications. For additional information, please contact the Colfax Fluid Handling Reliability Services office nearest you, or visit our website at www.circorrs.com.
  • Page 4: Product Description

    Only instrument air supply is required for operation. LubriMist® auto drain leg system is designed to collect and to reuse the oil  accumulated at the low point trap in the oil mist header piping layout. The low point trap is created as a result of elevation changes in the header layout where a continuous slope back to the mist generator is not possible.
  • Page 5: Typical Installation Diagrams

    V. Typical Installation Detail Diagrams  Open Loop Installation Detail Revision 3 9/28/2018...
  • Page 6  Closed Loop Installation Detail Revision 3 9/28/2018...
  • Page 7: Commissioning

    VI. Commissioning Ensure plugs have been installed in all connections that are not being used.  Verify grounding to pump is done.  Add an appropriate amount of oil about one gallon (3.8 Liters) to the  reservoir. Important: Test oil must be the same oil being used on the oil mist system.
  • Page 8: Drawings And Parts

    IX. Drawings and Parts A. Auto Drain Leg Assembly - P/N 77700304 Revision 3 9/28/2018...
  • Page 9 Revision 3 9/28/2018...
  • Page 10 B. Pneumatic Level Switch - P/N 77600853 Turn Operation Check Knob  Counter-Clockwise To Manually Raise The Float. Turn Operation Check Knob  Clockwise To Manually Lower The Float. Revision 3 9/28/2018...
  • Page 11 Adjustable Span To Set Desired Float Level. Drain Leg Manifold – P/N 77600873 (SS T304)  P/N 77600820 (Alum)  Revision 3 9/28/2018...
  • Page 12 Air Operated Diaphragm Pump – P/N D32911 Revision 3 9/28/2018...