Please read these instructions carefully before installing and using the product. Keep the instructions handy for future reference. Electrical
wiring must only be done by a licensed electrician and a "Certificate of Compliance" must be issued on completion of the installation.
WHAT'S IN THE BOX
• Bathroom unit
• Operating and Installation Instructions.
• Wall plate and switch.
• 1 x LED Light Panel
• Cutout Template
SAFETY INSTRUCTIONS
During use of the product, it is necessary to observe some precautions. Improper operation with disregard of precautions may result in infliction
of harm to health of the user and other people, as well as in infliction of damage to their property.
• Use only the voltage specified on the rating plate of the heater.
• This item should only be installed by a licensed tradesperson.
• The heater should be connected to the electric mains equipped with an automatic circuit breaker.
• The unit must be handled with care avoiding any sudden impacts or vibrations.
WARNING: FIRE RISK EXISTS IF THE HEATER IS COVERED BY OR POSITIONED CLOSE TO CURTAINS OR
• Do not use the appliance areas where gasoline, paint or other flammable liquids are used or stored.
• Do not use the appliance in particularly in dusty or where explosives are stored.
• Do not use the appliance in a building site, green house, barn or in animal stables.
• Do not use the appliance as a sauna heater.
• Do not use this unit in the place of animal propagating and rising.
• Warming: To avoid burns, do not touch the appliance surface by hand and other body parts. It is also necessary to avoid touching the heater
whilst the appliance is switched on, as severe burns may result. The appliance can take up to 1 hour to cool down after switching it off.
• Do not place any items of clothing, hand towels or similar over the heater to dry. Risk of overheating and fire hazard.
• Do not leave the heater unattended whilst in use.
• Do not use this heater on a wet surface, or where it can fall or be pushed into water.
• Do not reach for an appliance that has fallen into water. Switch off at supply and unplug immediately.
• If the heater is defective, it must be checked and repaired by the manufacturer, its service agent or similarly qualified persons for repair.
• Do not operate appliance with wet hands.
• Use this appliance only as described in this manual. Any other use is not recommended by the manufacturer and may cause fire, electric
shock or injury.
• Do not use abrasive cleaning products on this appliance. If the body becomes dirty, wipe off dust with a cloth. Always remove plug from the
mains supply before cleaning.
VAPOUR
OTHER COMBUSTIBLE MATERIALS.
www.martecaustralia.com.au | 02 8778 7500 | sales@martecltd.com.au
Model No: MBHV2000W
Installation Instructions
Page 1 of 5

Advertisement

Table of Contents
loading

Summary of Contents for Martec VAPOUR MBHV2000W

  • Page 1 Model No: MBHV2000W Installation Instructions VAPOUR Vapour 3-in-1 Fan Heater, Light and Exhaust Please read these instructions carefully before installing and using the product. Keep the instructions handy for future reference. Electrical wiring must only be done by a licensed electrician and a “Certificate of Compliance” must be issued on completion of the installation. WHAT’S IN THE BOX •...
  • Page 2 Model No: MBHV2000W Installation Instructions VAPOUR Vapour 3-in-1 Fan Heater, Light and Exhaust • The heater must be installed at least 1.8 m above the floor. • The heater must not be located immediately below a socket outlet. The heater must not be located in front of a socket outlet. They should be located outside the physical footprint of the units to minimize heat build up behind the heater.
  • Page 3: Installation

    Model No: MBHV2000W Installation Instructions VAPOUR Vapour 3-in-1 Fan Heater, Light and Exhaust LOCATION • The unit must be located and installed in accordance with AS/NZS 3000 and local building codes relating to damp situations. • This may mean that no part of the Module may be located directly above any part of a bath or shower recess or enclosure. •...
  • Page 4: Connection To Electric Mains

    Model No: MBHV2000W Installation Instructions VAPOUR Vapour 3-in-1 Fan Heater, Light and Exhaust CONNECTION TO ELECTRIC MAINS • Locate the heater in accordance with the requirements of the current Australian/New Zealand Wiring Rules AS/NZS 3000 relating to damp situations. • The heater is designed for connection to the single-phase 220-240V~ 50HZ electric mains equipped with a earth wire. •...
  • Page 5: Care And Maintenance

    Model No: MBHV2000W Installation Instructions VAPOUR Vapour 3-in-1 Fan Heater, Light and Exhaust CARE AND MAINTENANCE • During the installation of this fan heater, please make sure that the person in the bathtub or shower can’t touch the electrical switches and other electrical controllers. •...
  • Page 6: Warranty Statement

    2. The 2 year “In Home” warranty does not extend to the Martec Product accessories such as remote controller kits and/or light fittings (including glass light shades) that have been fitted during or after the original Martec Product installation.
  • Page 7 11. This warranty does not cover electrical humming noises, wobbling or any other external influences. 12. Martec Pty Ltd reserves the right to change or amend any or all parts of this warranty statement at any time and without notice.
  • Page 8: Customer Service

    NOTE: Stainless steel requires regular cleaning; “Tea Staining” is a common occurrence with all types of stainless steel. This is not considered a fault of the product and is not covered under warranty. Martec’s Precision 316, while made from Marine Grade 316 stainless steel, should only be used in a covered or enclosed outdoor environment as the fan is not hermetically sealed and will eventually rust internally.
  • Page 9 I, the Customer, acknowledge that I will be liable for this charge should the authorised Martec Service Agent determine this to be the case. Failure to pay warranty recovery charges issued by Martec Pty Ltd will result in the termination of any remaining warranty, in addition to possible debt collection procedures.

Table of Contents