Troubleshooting - North Star A1573001 Owner's Manual

Pressure washer pump
Hide thumbs Also See for A1573001:
Table of Contents

Advertisement

Problem
Motor will not start
Low/Surging pressure or no water flow
No chemical injection
A- Tripped GFCI cord
B- Tripped motor relay
C- Insufficient water supply
D- Plugged pump inlet filter
E- Wrong nozzle
F- Plugged nozzle
G- Worn nozzle
H- Leak in pressure hose
I- Wrong nozzle
J- Back pressure from extra long discharge hose
K- Leak in chemical siphon hose
L- Chemical strainer not submerged
The manufacturer reserves the right to make improvements in design
and/or changes in specifications at any time without incurring any
obligation to install them on units previously sold.
Any Questions, Comments, Problems or Parts Orders
Call NorthStar Product Support 1-800-270-0810

Troubleshooting

Cause
SOLUTION: A,B
SOLUTION: C,D,E,F,G,H
SOLUTION: I,J,K,L
Reset GFCI cord
Reset motor
See water supply section of this manual
See maintenance section of this manual
Make sure high-pressure nozzle is being used
Remove nozzle, check for blockage
Replace nozzle
Replace pressure hose
Make sure chemical nozzle is being used
Try shorter hose
Replace hose – use hose clamps if necessary
Make sure strainer is completely submerged