10. ACCESS TO MANUAL MODE OF THE MACHINE

Access keys SET and + and – for 5 seconds
During this phase all the controls and protection systems of the ACTIVE DRIVER are
disabled!
Keys pressed
SET and + and – Press them together for a few moments until the display shows MA
+
Increases the frequency and rotation of the electropump
Decreases the frequency and rotation of the electropump
Moves on to the next item in the following menu
FP = Setting of the test frequency in manual mode (Hz)
UP = Display of pressure (bar)
MODE
C1 = Display of the electropump phase current (A)
rt = Setting of the direction of rotation
UF = Display of flow
ZF = Display of zero flow
MODE and –
The electropump runs at the set frequency as long as the keys are held down
MODE and – and
The electropump remains operating at the set frequency.
+
The electropump may be switched off by pressing SET (when SET is pressed a second time
(for 2 seconds)
it takes you out of the Manual Mode menu).
SET and –
Changes the direction of rotation of the electropump (active only with the pump running).
SET
Press to stop the electropump or to leave manual mode.
10.1 rt : setting the direction of rotation
In manual mode, irrespective of which heading you are under, you can always invert the direction of
rotation by simultaneously holding down the SET and – keys for 2 seconds, this command is active only
with the pump running.

10.2 Starting the electropump .

Pressing the MODE and – and + keys simultaneously stops the electropump at the frequency FP.
The running status remains until the SET key is pressed.
When the electropump is ON the display blinks quickly.
When the electropump is OFF the display blinks slowly.
In manual mode, pressing the SET key takes you out of the menu, but if the electropump has been
started, pressing the key stops only the electropump; when the electropump is stopped, pressing SET
takes you out of the menu.
11.
GENERAL SYSTEM RESET
Access keys MODE and SET and + and –
To restart the appliance without disconnecting the power supply press the 4 keys simultaneously.
12.
RESTORING THE FACTORY SETTINGS
Access keys SET and +
for 2 seconds when switching on
The factory settings are indicated in table no. 14 on page 53.
To reset the factory values:
Switch off the appliance, press and hold down the SET and + keys while switching on the appliance again,
release the two keys only when the letters EE appear. In this case the ACTIVE DRIVER restores the factory
settings. When it has finished setting all the parameters the ACTIVE DRIVER returns to normal operation.
In this phase, in the models in which RC is active, the motor current is set at 0 as factory
default, so when you try to start the electropump it will immediately give the error EC. Go to
the installer's display and settings menu (keys MODE and SET and – for 5 seconds ) and set the
correct motor data plate current (parameter rC as in paragraph 8.5.1.)
13.
ERROR AND STATUS CONDITIONS
The ACTIVE DRIVER is equipped with protection systems to preserve the pump, the motor, the
supply line and the ACTIVE DRIVER itself.
If one or more protections trip, the one with the highest priority is immediately notified on the display.
Depending on the type of error the electropump may switch itself off, but when normal conditions are restored
the error status may be cancelled immediately or only after a certain time, following an automatic reset.
ENGLISH
Use of the keys
Action
MODE and SET and + and –
50
(ref. Table no. 14 page 53)
at the set FS value
(ref. Table no. 14 page 53)
(ref. Table no. 14 page 53)
(ref. Table no. 14 page 53)

Advertisement