DAB PUMPS ACTIVE DRIVER M/M 1.1 Instruction For Installation And Maintenance

Hide thumbs Also See for ACTIVE DRIVER M/M 1.1:

Advertisement

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE
ACTIVE DRIVER M/M 1.1
ACTIVE DRIVER M/T 1.0
ACTIVE DRIVER M/T 2.2
ACTIVE DRIVER T/T 3.0
ACTIVE DRIVER T/T 5.5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACTIVE DRIVER M/M 1.1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DAB PUMPS ACTIVE DRIVER M/M 1.1

  • Page 1 INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE ACTIVE DRIVER M/M 1.1 ACTIVE DRIVER M/T 1.0 ACTIVE DRIVER M/T 2.2 ACTIVE DRIVER T/T 3.0 ACTIVE DRIVER T/T 5.5...
  • Page 2 − Direttiva Bassa Tensione 73/23 e successive modifiche. DÉCLARATION DE CONFORMITÉ La société DAB PUMPS s.p.a. – Via M. Polo, 14 – Mestrino (PD) – ITALY – sous sa propre responsabilité exclusive déclare que les produits susmentionnés sont conformes à: −...
  • Page 3: Uygunluk Beyannamesi̇

    ACTIVE DRIVER T/T 3.0 - ACTIVE DRIVER T/T 5.5 ∆ΗΛΩΣΗ ΣΥMMOPΦΩΣΗΣ Η εταιρεία DAB PUMPS s.p.a. – Via M. Polo, 14 – Mestrino (PD) – ITALY – δηλώνει νπεύθυνα πως τα πρϊόντα που αναφέρονται παραπάνω, εναρµονίζονται µε: − Тην οδηγία περί µαγνητικής συµβατότητας 89/336/EOK και µετέπειτα τροποποιήσεις.
  • Page 4: Particular Warnings

    In determined calibration conditions, after a power cut the converter may start automatically. Pay attention: the motor terminals U, V and W (for the Active Driver M/M 1.1 the motor terminals R and S). may carry dangerous voltages even when the converter is not operating.
  • Page 5 The motor of the installed electropump must comply with the data in the table in Chapter 4. The user connected to the ACTIVE DRIVER M/M 1.1 must not exceed 8,5 A as phase current. The user connected to the ACTIVE DRIVER M/T 1.0 must not exceed 4,7 A as phase current.
  • Page 6: Hydraulic Connections

    ENGLISH The ACTIVE DRIVER is already provided with current protections. If a magnetothermal switch is installed in line, it must have a max. capacity of 16A. The connection of the line to the ACTIVE DRIVER must include the earth line. The total earth resistance must not exceed 100 Ohm.
  • Page 7 ENGLISH Ref. FUNCTION 0V connection terminal (GND) for joining I to GND. J22 - 6 (excluding A.D. M/M 1.1 and A.D. M/T 1.0) Connection terminal: 0V DC (GND). J22 - 7 (excluding A.D. M/M 1.1 and A.D. M/T 1.0) Remote alarm connection terminal. (excluding A.D. M/M 1.1 and A.D. M/T 1.0) J14 –...
  • Page 8 ENGLISH OPERATION : PARAMETERS FOR THE USER Access keys MODE & SET for 2 seconds 8.3.1 SP : Setting the set point pressure ( in bar ) From normal operating status, hold down the MODE and SET keys simultaneously until the letters SP appear on the display.
  • Page 9 ENGLISH 8.4.3 od: Setting the operating mode of the ACTIVE DRIVER Possible values: 1 and 2 The ACTIVE DRIVER leaves the factory in mode 1 for working without expansion vessels or with small vessels. If there is an expansion vessel near the ACTIVE DRIVER, with a half-inch or larger fitting, you must change to mode 2.
  • Page 10 ENGLISH OPERATION : TECHNICAL ASSISTANCE DISPLAYS AND SETTINGS Access keys MODE & SET & + for 5 seconds 8.5.1 tb: Setting the reaction time of the water lack blockage The setting of the reaction time of the water lack blockage allows you to select the time (in seconds) taken by the ACTIVE DRIVER system to indicate the lack of water in the electropump.
  • Page 11 ENGLISH CM = 1 : The primary and secondary ACTIVE DRIVER alternate in being the regulation leader. The exchange takes place each time the leader ACTIVE DRIVER goes into stand-by mode or after 2 hours of continuous activity. If during operation the leader electropump is unable to satisfy the user and the secondary electropump is set as a booster (Eb=2), the latter will work at maximum frequency, while the leader ACTIVE DRIVER will continue to modulate the rotation frequency according to the user.
  • Page 12: Monitor Displays

    ENGLISH 8.5.11 O1: Setting output 1 function ( “active alarm” ) (excluding A.D. M/M 1.1 and A.D. M/T 1.0) O2: Setting output 2 function ( “pump operating ) (excluding A.D. M/M 1.1 and A.D. M/T 1.0) Assigning the parameters that associate functions with the digital outputs OUT1; OUT2 Assigning the Value parameters...
  • Page 13 ENGLISH Use of the keys. Keys pressed Action “SET” & “+” & “-“ Press them together for a few moments until the display shows MA Increases the frequency and rotation of the electropump Decreases the frequency and rotation of the electropump Moves on to the next item in the following menu FP = Setting of the test frequency in manual mode (Hz) ≤...
  • Page 14 ENGLISH 13.1 “bL” Blockage due to water lack In conditions of zero flow the system switches off the pump. If, by mistake, a pressure set-point is set which is higher than the maximum pressure that the electropump can supply, the system indicates “blockage due to water lack”...
  • Page 15: Indications On The Display

    ENGLISH INDICATIONS ON THE DISPLAY Identifying s. Description Factory parameters A.D. A.D. A.D. A.D. A.D. Indications on the display in normal operation M/M 1.1 M/T 1.0 M/T 2.2 T/T 3.0 T/T 5.5 Electropump operating Electropump waiting User displays and settings (keys MODE & SET 2 seconds ) Setting the set-point pressure ( in bar ).
  • Page 16 DAB PUMPS S.p.A. DAB PUMPS Ltd DAB PUMPS B.V. Via M. Polo, 14-35035 Mestrino (PD) - Italy Albert Einsteinweg, 4 Unit 4,Stortford Hall Industrial Park, Tél. +39 049 90 48811 - Fax + 39 049 9048847 NL - 5151 DRUNEN Dunmow Road, Bishops Stortford, http://www.dabpumps.com...