3.5.
Measuring Resistance
3.5.1.
Connect the black lead to the COM input socket and the red test lead to the the V/Ω input socket (the polarity of the red lead is ‘+’).
3.5.2.
Set the rotary switch to the required ‘Ω’ range and connect the test leads across the resistance under measurement.
3.5.3.
When checking in-circuit resistance, ensure that the circuit under test has all power removed and all capacitors have been fully discharged.
3.6.
Continuity Testing
3.6.1.
Connect the black lead to the COM input socket and the red lead to to the V/Ω input socket (the polarity of the red lead is ‘+’).
3.6.2.
If the circuit resistance under test is lower than 50Ω, the built-in buzzer will sound.
3.7.
Insulation Testing (with optional 500V insulation tester unit)
3.7.1. Set The rotary switch to the 2000MΩ external unit range. The display value will be unstable until a reading is taken, this is normal in
this range.
3.7.2. Insert the three tester unit jacks VΩ, COM and EXT into the MM404 input sockets VΩ, COM and EXT.
3.7.3. Set the insulation tester unit to the 2000MΩ position.
3.7.4. Connect the insulation tester unit’s L and E terminals to the installation under test. (The test installation’s power must be off).
p WARNING! Never perform insulation measurements on live circuits.
3.7.5. Set the insulation tester power switch to the on position.
3.7.6. Press the 500V push switch, the red led will light up. The clamp meter will display the insulation value.
3.7.7. If the reading is below 19MΩ, change the MM404 range to the 20MΩ external unit setting to improve the accuracy.
3.7.8. When not in use the tester unit must be switched off and all leads removed.
For more in depth instructions refer to the manual supplied with your MM404.261 Insulation Tester.
4.
SPECIFICATION
AC CURRENT
Range
Accuracy
200A
±2% of reading +5 digits 100mA
1000A
±2% of reading +5 digits
for 800A and below
±3% of reading +5 digits above 800A
Overload protection: 1200A within 60 seconds
AC VOLTAGE
Range
Accuracy
750V
±1% of reading +4 digits
Input impedance: 9MΩ
Overload protection:750V AC/DC on all ranges
Insulation Test (with optional 500V test unit)
Range
Accuracy
20MΩ
±2% of reading +2 digits
200MΩ ±4% of reading +2 digits
for 500MΩ and below
±5% of reading +2 digits for greater than 500MΩ
5.
MAINTENANCE
WARNING! Before attempting to open the case, ensure that test leads have been disconnected from measurement circuits to avoid
p
electric shock hazard.
5.1.
If the battery sign
cover retaining screw and slide off the back cover. Replace the battery. (9V PP3)
5.2.
SPARE PARTS
6.
DECLARATION OF CONFORMITY
Declaration of Conformity We, the sole UK importer, declare that the product listed below is in conformity with the following standards and directives.
DIGITAL MULTIMETER
Model: MM.404
73/23/EEC Low Voltage Directive
93/68/EEC CE Marking Directive
89/336/EEC EMC Directive
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this equipment.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Resolution
1A
Resolution
1V
RESISTANCE.
Resolution
Range
10KΩ
200Ω
1MΩ
20KΩ
Overload Protection. 500VDC/rms AC on all ranges.
appears on the LCD display, it indicates that the battery should be replaced. Remove the rear
MM404.01
TEST LEADS
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
DC VOLTAGE (auto ranging)
Range
Accuracy
1000V
±0.5% of reading ±1 digit
Input impedance: 9MΩ
Overload Protection: 1000V DC/peak AC on all
ranges
CONTINUITY TEST
Range
200Ω
Buzzer Sound
50 ± 25Ω
Overload Protection
500VDC /rms AC
Accuracy
± 1% of reading ±3 digits
± 1% of reading ±1 digits
The construction file for this product is held by the Manufacturer and may be inspected,
by a national authority, upon request to Jack Sealey Ltd.
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole UK importer of Sealey Professional Tools.
01284 757500
01284 703534
Resolution
1V
Resolution
0.1Ω
10Ω
1st September 2004
www.sealey.co.uk