Download Print this page

OEM HVPS-300 User Manual page 7

High voltage power supply with bipolar output

Advertisement

Safety
Warning! This equipment produces high voltages that can be very dangerous.
Assemble the entire setup before powering up the device.
• Power supply enclosure to be protectively grounded via provided grounding stud.
• Use low voltage power supply with DC output galvanically insulated from AC input
(insulation strength 4000VAC, 2500VAC or 1500VAC is selected in dependence on your
application)
• Do not connect / disconnect output cables while driver is turned on
• Do not operate with disconnected load
• Avoid casual contacts of personnel with output cables and with the load
• Do not turn the power supply on if it was already damaged with water, chemicals,
mechanical or electrical shock
• Do not self-repair the power supply, there are no user-serviceable parts inside
Operations
1 Ensure 24V DC power supply is off
2 Connect HVPS-300 to the load and to 24V DC power supply.
Do not apply 24V DC power until the setup is completely assembled
3 Disable HVPS-300 (pin 2 of Interface)
4 Set HV Program to 0V (pins 7 and 9 of Interface)
5 Apply 24V DC power to HVPS-300
6 Set HV Program to the desired value (pins 7 and 9 of Interface)
7 Enable HVPS-300 (pin 2 of Interface)
Don't be careless around the equipment.

Advertisement