"ENABLE" JUMPER, "HV PROGRAM" JUMPER
AND "HV PROGRAM" TRIMPOT:
Warning! In stand-alone regime high voltage appears at power supply's
output once the device is powered. Thus, we do not recommend using power supply in stand-
HVPS-300 might be used in stand-alone regime. In this case, Enable jumper should be
used instead of Enable signal, HV Program jumper along with HV Program trimming
potentiometer should be used instead of HV Program signal.
Enable jumper is set between pins 1 and 2.
HV program jumper is set between pins 9 and 10.
HV OUTPUT (DSUB 3W3 MALE):
All pins are high voltage contacts by Harting (09692812550).
PIN (color)
A1 (blue)
A2 (black)
A3 (red)
alone regime, do this on your risk only.
DESIGNATION
HV Negative
GND
HV Positive
DESCRIPTION
High voltage of negative polarity (-V/2)
appears on this pin once power supply's
output is enabled
HV output ground potential
High voltage of positive polarity (+V/2)
appears on this pin once power supply's
output is enabled