Download Print this page

Specification - Sealey PRS6400 Manual

Premier 12/24v 6400a wheeled roadstart jump starter

Advertisement

To reduce the risk of damage to the electric plug or cord, pull by the plug rather than the cord when disconnecting the Roadstart.
9
To reduce the risk of electric shock, unplug the Roadstart charger from the outlet before attempting any maintenance or cleaning.
9
Simply turning off the controls will not reduce this risk.
DO NOT operate the Roadstart or charger with a damaged output cable; have the damaged part replaced immediately by a qualified
8
service person.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid
9
a hazard.
NEVER wait until the Roadstart is completely discharged before recharging.
8
DO NOT operate the Roadstart if it has received a sharp blow, been dropped or otherwise damaged in any way; take it to a qualified
8
service person.
DO NOT disassemble the Roadstart or charger; take it to a qualified service person when service or repair is required. Incorrect
8
reassembly may result in a risk of fire or electric shock.
RISK OF EXPLOSIVE GASES. PREVENT FLAMES AND SPARKS. PROVIDE ADEQUATE VENTILATION DURING CHARGING.
WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES
DURING NORMAL OPERATION. FOR THIS REASON, IT IS IMPORTANT THAT YOU FOLLOW THESE INSTRUCTIONS EACH
TIME YOU USE THE ROADSTART.
The Roadstart must be placed in a well-ventilated area.
9
To reduce the risk of a battery explosion, follow these instructions and those published by the battery manufacturer and the
9
manufacturer of any equipment you intend to use in the vicinity of the battery. Review the cautionary markings on these products and
on the engine.
1.3.
PERSONAL PRECAUTIONS
RISK OF EXPLOSIVE GASES. A SPARK NEAR THE BATTERY MAY CAUSE A BATTERY EXPLOSION. TO REDUCE THE RISK
OF A SPARK NEAR THE BATTERY:
NEVER smoke or allow a spark or flame in the vicinity of a battery or engine.
9
DO NOT permit the internal battery of the Roadstart to freeze. Never charge a frozen battery.
8
When charging the internal battery, work in a well ventilated area and do not restrict the ventilation in any way.
9
Be sure the area around the battery is well ventilated while the Roadstart is being used.
9
Remove personal metal items such as rings, bracelets, necklaces and watches when working with a lead-acid battery. A lead-acid
9
battery can produce a short-circuit current high enough to weld a ring or the like to metal, causing a severe burn.
Be extra cautious, to reduce the risk of dropping a metal tool onto the battery. It might spark or short-circuit the battery or other
9
electrical part that may cause an explosion.
To prevent sparking, NEVER allow clamps to touch together or contact the same piece of metal.
9
Consider having someone close enough by to come to your aid when you work near a lead-acid battery.
9
Have plenty of fresh water and soap nearby in case battery acid contacts your skin, clothing or eyes.
9
Wear complete eye and body protection, including safety goggles and protective clothing. Avoid touching your eyes while working near
9
the battery.
If battery acid contacts your skin or clothing, immediately wash the area with soap and water. If acid enters your eye, immediately flood
9
the eye with cold running water for at least 10 minutes and get medical attention right away.
If battery acid is accidentally swallowed, drink milk, the whites of eggs or water. DO NOT induce vomiting. Seek medical attention
9
immediately.
2. INTRODUCTION
High performance 66Ah AGM battery, specially formulated to jump-start up to 8-Cylinder engines up to 9.0L Diesel and 12.0L Petrol. Highly
durable casing and totally portable thanks to a retractable handle and puncture proof wheels. Easy to read digital voltmeter. 0/12/24v rotary
switch for spark free connection. Supplied with heavy duty brass clamps with inbuilt short circuit protection fuse ( in the + clamp) Reverse
polarity alarm, both visual and audible. 12V fused output socket can be used as a memory saver, as well powering accessories such as mini
compressors. Supplied with an automatic 12/24v 7A smart charger & maintainer. Made in Switzerland.

3. SPECIFICATION

Model No: ................................................................PRS6400
Auxiliary Output: ......................................................... 1 x 12V
Cable & Clamp Length: .................................................. 1.7m
Cold Cranking Amps: ...................... 2500A(12V)/1250A(24V)
Peak Amps: ..................................... 6400A(12V)/3200A(24V)
4. FEATURES
1. Reverse polarity alarm
2. Voltmeter
3. Charge status
4. Circuit breaker
5. On/off 12/24V switch
6. Charging input/output socket
Fuse Location:
7. Positive clamp handle cover
8. Fuse
fig.1
© Jack Sealey Limited
Original Language Version
PRS6400 Issue:1
23/01/23

Advertisement