POWERSTART200, POWERSTART350, POWERSTART500
Thank you for purchasing this Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: BEFORE USING THIS PRODUCT, PLEASE READ THE INSTRUCTIONS CAREFULLY. MAKE CAREFUL NOTE OF SAFETY INSTRUCTIONS,
WARNINGS AND CAUTIONS. THIS PRODUCT SHOULD ONLY BE USED FOR ITS INTENDED PURPOSE. FAILURE TO DO SO MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.
1. FEATURES
GENERAL FEATURES
Initial peak current: Powerstart200 ........1600 Amps
!
Powerstart350.......3200 Amps (12V)
Powerstart500 .......4000 Amps (12V)
Test switch and status meter.
!
Automatic mains powered charger unit.
!
Latest battery technology.
!
SAFETY FEATURES
Polarity-indicating LEDs prevent cross-connection.
!
The Powerstarts contain sealed lead-acid batteries. This means that the
!
Powerstart 200, 350 and 500 may be stored in any position without fear of leakage.
IMPORTANT: READ THE SAFETY INSTRUCTIONS BEFORE ATTEMPTING TO USE THE POWERSTART.
# WARNING! BEFORE CHARGING THIS UNIT, DISCONNECT THE OUTPUT LEADS FROM THE UNIT AS THEY WILL REMAIN "LIVE"
WHILE CHARGING.
# WARNING! NEVER CLAMP THE OUTPUT LEADS TO THE CARRY HANDLE AS THIS COULD RESULT IN SHORT CIRCUIT.
2. SPECIFICATIONS
Battery Type . . . . . . . . . . . . . . . . . . . . . . . . . .Genesis . . . . . . . . . . . . . . .Hawker . . . . . . . . . . . . . . .Hawker
Start Power . . . . . . . . . . . . . . . . . . . . . . . . . . . .200hp . . . . . . . . . . . . . . . .350hp . . . . . . . . . . . . . . . .500hp
DC Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12V . . . . . . . . . . . .12V . . .24V . . . . . . . . . . . .12V . . .24V
Peak Current . . . . . . . . . . . . . . . . . . . . . . . . . . .1600A . . . . . . . . . .3200A .1600A . . . . . . . . . .4000A .2000A
Cranking Current (20
C 5secs) . . . . . . . . . . . . . .680A . . . . . . . . . .1360A . .680A . . . . . . . . . .1500A . .750A
O
Cold Cranking Current (-18
C 30secs) . . . . . . . . .280A . . . . . . . . . . .560A . .280A . . . . . . . . . . .640A . .320A
O
Breakers (Charging Circuit Protection) . . .10A (Internal) . . . . .10A (External Reset) . . . . .10A (External Reset)
Charger Fuse . . . . . . . . . . . . . . . . . .630mA Antisurge . . . . . . . .630mA Antisurge . . . . . . . .630mA Antisurge
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10kg . . . . . . . . . . . . . . . . .19kg . . . . . . . . . . . . . . . . .17kg
Note: 'Start Power' indicates the size of engine that each Powerstart is capable of cranking.
3. SAFETY INSTRUCTIONS
# DANGER! RISK OF EXPLOSIVE GASES.
WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION.
FOR THIS REASON, IT IS VERY IMPORTANT TO READ AND FOLLOW THESE INSTRUCTIONS EXACTLY EACH TIME YOU USE THE POWERSTART.
IMPORTANT: To reduce risk of battery explosion, follow these instructions and those published by the battery manufacturer and the
manufacturer of any equipment you intend to use in vicinity of the battery. Remember to review warning marks on all products and on engines.
3.1.
PERSONAL PRECAUTIONS
Ensure that there is another person within hearing distance and close enough to come to your aid should a problem arise when working near
!
a lead-acid battery.
Have fresh water and soap nearby in case battery acid contacts skin, clothing or eyes.
!
Wear safety eye protection and protective clothing. Avoid touching eyes while working near battery.
!
Wash immediately with soap and water if battery acid contacts skin or clothing. If acid enters eye, flush eye immediately with cool, clean
!
running water for at least 15 minutes and seek immediate medical attention.
Remove personal metallic items such as rings, bracelets, necklaces and watches. A lead-acid battery can produce a short-circuit current
!
high enough to melt or weld a ring, which would cause severe burns.
3.2.
OTHER IMPORTANT SAFETY INSTRUCTIONS
Familiarise yourself with the application, limitations and potential hazards of the unit.
!
Keep the unit in good working condition. Take immediate action to repair or replace damaged parts.
!
Only use recommended attachments and parts. To use unapproved items may be dangerous and will invalidate your warranty.
!
The Powerstart must only be opened and checked by qualified service personnel. DO NOT disassemble for any reason.
!
Keep children and unauthorised persons away from the work area.
!
Keep work area clean and tidy and free from unrelated materials and ensure that there is adequate lighting.
!
If the unit receives a sharp knock or blow, it must be checked by a qualified service agent before being used.
!
DO NOT smoke or allow a spark or flame in the vicinity of the battery, engine or Powerstart.
"
DO NOT drop any metal tool onto the battery as it may produce a spark or short circuit, which could cause an explosion.
"
INSTRUCTIONS FOR:
PORTABLE JUMP START UNITS
Powerstart200
Powerstart350
Powerstart500
Powerstart200/350/500 - 2 - 040907
Need help?
Do you have a question about the POWERSTART200 and is the answer not in the manual?
Questions and answers