Huawei SUN2000-200KTL-H2 Quick Manual page 12

Hide thumbs Also See for SUN2000-200KTL-H2:
Table of Contents

Advertisement

Removing the Rubber Rings from the Crimping Module
4.5
Use scissors to cut off the joints of the rubber rings to remove them. All rubber rings are
removed in the same way.
(Optional) Installing the Solar Tracker Power Cable
4.6
1. A switch-disconnector-fuse or fuse-switch-disconnector with a voltage of no less than 800 V,
current of 16 A, and protection type of gM needs to be installed between the SUN2000 and
the tracker controller for protection.
2. The cable between the wiring terminal on the power cable and the switch-disconnector-fuse
or fuse-switch-disconnector should be less than or equal to 2.5 meters.
4.7
Installing AC Output Power Cables