Ametek Drexelbrook DR5400 Handbook

Ametek Drexelbrook DR5400 Handbook

24 ghz radar (fmcw) level transmitter for liquids in basic process applications
Table of Contents

Advertisement

Quick Links

DR5400
DR5400
DR5400
DR5400
Handbook
Handbook
Handbook
Handbook
24 GHz Radar (FMCW) Level Transmitter for liquids in
basic process applications
© AMETEK Drexelbrook - DR5400-PM-English-Issue 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DR5400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ametek Drexelbrook DR5400

  • Page 1 DR5400 DR5400 DR5400 DR5400 Handbook Handbook Handbook Handbook 24 GHz Radar (FMCW) Level Transmitter for liquids in basic process applications © AMETEK Drexelbrook - DR5400-PM-English-Issue 1...
  • Page 2 IMPRINT :::::::::::::::::::::::::::::::::: All rights reserved. It is prohibited to reproduce this documentation, or any part thereof, without the prior written authorisation of AMETEK Drexelbrook. Subject to change without notice. Copyright 2019 by AMETEK Drexelbrook www.drexelbrook.co 01/2019 - DR5400-PM-English-Issue 1...
  • Page 3: Table Of Contents

    3.10.1 How to attach the weather protection to the device............45 3.10.2 How to open the weather protection .................. 47 4 Electrical connections 4.1 Safety instructions......................48 4.2 General notes ......................... 48 4.3 Electrical installation: output options with cable gland ..........49 DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 4 7.1 Periodic maintenance....................122 7.1.1 General notes........................122 7.1.2 Maintenance of the O-rings for the housing covers............122 7.1.3 How to clean the top surface of the device................. 123 7.1.4 How to clean horn antennas under process conditions............. 123 www.drexelbrook.co DR5400-PM-English-Issue 1...
  • Page 5 9.10 HART® menu tree for PDM..................162 9.10.1 Overview PDM menu tree (positions in menu tree)............163 9.10.2 PDM menu tree (details for settings) ................164 10 Appendix 10.1 Order code ........................167 10.2 Spare parts ......................... 173 10.3 Accessories: general items..................176 DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 6 CONTENTS DR5400 10.4 Accessories: process connection kits................ 177 10.5 Glossary ........................179 11 Notes www.drexelbrook.co DR5400-PM-English-Issue 1...
  • Page 7: Safety Instructions

    — 2019-03-27 HMI (LCD display BL1.31.06 ER2.0.0_ 4002905801b DR5400-PM- option) Issue 1 Main and Support 4002815701f Sensor 4002859301a 1 If the device does not have the display module option, the module reference number is 4002905802a DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 8: Intended Use

    Declaration of Conformity. You can download this document free of charge from the website. All devices are based on the CE marking and meet the requirements of NAMUR Recommendations NE 21, NE 43, NE 53 and NE 107. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 9: Radio Approvals

    2 HVIN (Hardware Version Identification Number). This number gives the radar signal frequency (24GHZ = 24 GHz), the location of the device (T=TLPR or L=LPR) and the type of signal converter (compact (C)) TLPR device: HVIN: 24GHZ-T-C LPR device: HVIN: 24GHZ-L-C 3 CE sign DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 10 If it is necessary to install the device less than 4 km / 2.485 mi from radio astronomy sites, you must get the approval of the national regulatory authority before installation (e.g. ANFR (France), Bundesnetzagentur (Germany), Ofcom (United Kingdom) etc.). www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 11 Bleien 47°20’26" N 08°06’44" E Sweden Onsala 57°23’45" N 11°55’35" E Cambridge 52°09'59" N 00°02'20" E Darnhall 53°09'22" N 02°32'03" W Jodrell Bank 53°14'10" N 02°18'26" W Knockin 52°47'24" N 02°59'45" W Pickmere 53°17'18" N 02°26'38" W DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 12: And Canada

    Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is • connected. Consult the dealer or an experienced radio/TV technician for help. • www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 13 Director of the DRAO before the equip- ment can be installed or operated. The Director of the DRAO may be contacted at 250-497-2300 (tel.) or 250-497-2355 (fax). Alternatively, the Manager, Regulatory Standards, Industry Canada, may be contacted. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 14 (T=TLPR or L=LPR) and the type of signal converter (compact (C)) TLPR device: HVIN: 24GHZ-T-C LPR device: HVIN: 24GHZ-L-C 3 FCC ID and IC number TLPR device: FCC-ID:Q6BFMCW24G74T, IC number: 1991D-FMCW24GX4T LPR device: FCC-ID: Q6BFMCW24G74L, IC number: 1991D-FMCW24GX4L www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 15: Safety Instructions From The Manufacturer

    The manufacturer reserves the right to alter the content of its documents, including this disclaimer in any way, at any time, for any reason, without prior notification, and will not be liable in any way for possible consequences of such changes. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 16: Product Liability And Warranty

    This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. Special considerations and precautions are also described in the document, which appear in the form of icons as shown below. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 17: Warnings And Symbols Used

    In general, devices from the manufacturer may only be installed, commissioned, operated and maintained by properly trained and authorized personnel. This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 18: Device Description

    Antenna extensions are available for this device. These are supplied attached to the device. If the antenna extensions are too long, the device will be supplied in two parts. For more data about the assembly procedure, refer to How to attach antenna extensions on page 41 www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 19: Device Description

    ) Metallic Horn antenna option is specially made for the BM 26 A magnetic level indicator. INFORMATION! Accessories: Accessories: Accessories: Accessories: For more data about general items, refer to Accessories: general items on page 176 . For more Accessories: process connection kits on page 177 data about process connections, refer to DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 20: Visual Check

    Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. INFORMATION! Compare the material references on the side of the process connection with the order. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 21: Nameplates

    11 cQPSus electrical safety certification for the USA and Canada. Agrees with NEC and CEC requirements for installa- tion in ordinary locations. 12 WARNING! Hot surface. If the device is connected to tank that operates at high temperature, there is a risk of injury. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 22: Installation

    2 Put the device on its side. We recommend that you use the packaging in which it was delivered. 3 Storage temperature range: -40...+85°C / -40...+185°F • Store the device in a dry and dust-free location. • Keep the converter out of the sunlight. • Store the device in its original packing. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 23: Transport

    • Protect the signal converter from direct sunlight. If necessary, install the weather protection accessory. • Do not subject the signal converter to heavy vibrations. The devices are tested for vibration and agree with EN 50178 and IEC 60068-2-6. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 24: Pressure And Temperature Ranges

    +212 Metallic Horn +130 +266 1 The maximum process connection temperature must agree with the temperature limits of the gasket material Guidelines for maximum operating pressure For more data on pressure ratings, refer to on page 137. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 25: Recommended Mounting Position

    If there is a nozzle on the tank before installation, the nozzle must be a minimum of 200 mm / ¨ from the tank wall. The tank wall must be flat and there must not be obstacles adjacent to the nozzle or on the tank wall. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 26 Figure 3-6: There is no maximum limit to the number of devices that can be operated in the same tank There is no maximum limit to the number of devices that can be operated in the same tank. They can be installed adjacent to other radar level transmitters. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 27: Tanks With Dish-Shaped And Conical Bottoms

    Dish-shaped or conical bottoms have an effect on the measuring range. The device cannot measure to the bottom of the tank. If possible, install the device as shown in the illustration that follows: Figure 3-7: Tanks with dish-shaped or conical bottoms 1 Axis of radar beam 2 Minimum level reading DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 28: Mounting Restrictions

    Do not put the device immediately above equipment and obstacles in a tank or pit. This can have an effect on the performance of the device. INFORMATION! If possible, do not install a nozzle on the tank centerline. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 29 Metallic Horn, DN150 (6¨) 6° Metallic Horn, DN200 (8¨) 5° PP Drop DN80 (3¨) 9° PP Drop, DN100 (4¨) 7° PP Drop, DN150 (6¨) 5° 1 This antenna option is specially made for the BM 26 A DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 30: Process Connections

    Figure 3-10: Flange connections: installation procedure Ød = nozzle diameter h = nozzle height Recommended nozzle size for flange connections The nozzle must be as short as possible. Refer to the table below for the maximum height of the nozzle: www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 31 • Make sure that you point the device in the correct direction. For more data, refer to notes on page 25 ("Point the device in the correct direction"). • Tighten the flange bolts. Refer to local rules and regulations for the correct torque to apply to the bolts. End of the procedure. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 32 All antennas with one or more antenna extensions: Attach the locking screw to the top All antennas with one or more antenna extensions: antenna extension with a 3 mm Allen wrench. • Put the device carefully on the tank flange. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 33 Equipment needed: • Device • Gasket for G 1½ connection (not supplied) • Thread seal tape (PTFE) for 1½ NPT connection (not supplied) • 50 mm open-end wrench (not supplied) DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 34 If the antenna is larger than the process connection, we recommend that you use an antenna extension. It is possible that there is not sufficient space to tighten the antenna locking screw. • Make sure the tank connection is level. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 35 If the device has antenna extensions, this option extends the maximum nozzle height. Each antenna extension has a length of 105 mm / 4.1 . The maximum number of antenna extensions ¨ that can be attached to the device are: Metallic Horn antenna: 10 • • PP Drop antenna: 5 DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 36: Lpr Devices: Recommendations For Pits And Tanks Made Of Non-Conductive Materials

    Open pits Figure 3-15: Open pits If the device must measure the level of product in a pit, you can attach a support to the side of the pit or above the pit. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 37: Standpipes (Stilling Wells And Bypass Chambers)

    The standpipe must be vertical. • Recommended surface roughness: < 0.1 mm / 0.004 • ± ¨ Make sure that there are no deposits at the bottom of the standpipe. • Make sure that there is liquid in the standpipe. • DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 38 If the device must be installed on a tank with a floating roof, install it in a stilling well made of metal. Figure 3-17: Floating roofs 1 Sediment 2 Support fixtures 3 Stilling well 4 Floating roof 5 Product 6 Tank www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 39 C2.7 Mult. Refl. Enable function to "Enable" to keep the effects of multiple reflections C2.7 Mult. Refl. Enable C2.7 Mult. Refl. Enable to a minimum. For more data, refer to Function description on page 81 (C. Full Setup). DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 40 • Additional process connections are necessary for the liquids to circulate freely along the length of the bypass chamber. Figure 3-19: Installation recommendations for bypass chambers that contain more than one liquid 1 Bypass chamber 2 Additional process connection www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 41: How To Attach Antenna Extensions

    • If you changed the antenna extension value, also change the blocking distance value. Push [^ ^ ^ ^ ], 3 × [ ], [> > > > ] to go to menu item C1.5 Blocking Distance C1.5 Blocking Distance. C1.5 Blocking Distance C1.5 Blocking Distance DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 42 • DN150 (6¨) Drop antenna: M6 × 40 (quantity: 3) Procedure 1: How to attach an antenna extension 1 Remove the O-rings from the plastic sachet supplied with the device. Put an O-ring 4 into the groove at the top of each antenna extension. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 43 • Push 3 × [^ ^ ^ ^ ] to go back to the "Save Configuration?" screen. • Push [ ] or [ ] to set the screen to Yes Yes and push [^ ^ ^ ^ ] to store and use the changed settings. End of the procedure. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 44: How To Turn Or Remove The Display Module (Option)

    If there is an object adjacent to the device that makes it difficult to read the display, you can rotate the display in increments of 90°. Figure 3-22: How to turn or remove the display module (option) Equipment needed: • Cover wrench • Display extractor CAUTION! Disconnect the power supply. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 45: Weather Protection

    1 Weather protection cover (with an R-clip to hold the cover on the clamp) 2 Device 3 Weather protection clamp (2 parts) 4 2 locking nuts 5 10 mm socket wrench (not supplied) The overall dimensions of the weather protection are on page 140. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 46 3 Lower the weather protection cover onto weather protection clamp until the hole for the lock is in the slot at the front of the cover. 4 Put the R-clip into the hole at the front of the weather protection cover. 5 End of the procedure. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 47: How To Open The Weather Protection

    Figure 3-25: How to open the weather protection 1 Remove the R-clip from the hole at the front of the weather protection cover. 2 Remove the weather protection cover. 3 Lift the display screen cover. End of the procedure. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 48: Electrical Connections

    Devices with the PROFIBUS PA output option: Devices with the PROFIBUS PA output option: Devices with the PROFIBUS PA output option: Devices with the PROFIBUS PA output option: For electrical connection data, refer to the "Description of PROFIBUS PA interface" supplementary instructions. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 49: Electrical Installation: Output Options With Cable Gland

    Use the applicable electrical cables with the cable glands. • Make sure that the current is not more than 5 A or that there is 5 A-rated fuse in the • electrical circuit that energizes the device. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 50 • 3 mm Allen wrench (not supplied) • Cover wrench Procedure 1 Loosen the lock screw with a 3 mm Allen wrench. 2 Remove the cover stop. 3 Turn the cover counterclockwise with the cover wrench. 4 Remove the cover. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 51 1 Loosen the cable gland. Put the electrical wires into the cable entry. Loosen the terminal screws with a POZIDRIV® PZ1 screwdriver. Connect the electrical wires to the connector. 2 Tighten the terminal screws with a POZIDRIV® PZ1 screwdriver. 3 Tighten the cable gland. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 52 • 3 mm Allen wrench (not supplied) 1 Put the cover on the housing 2 Turn the cover clockwise until it is fully engaged. 3 Attach the cover stop and lock screw. 4 Tighten the lock screw with a 3 mm Allen wrench. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 53: Electrical Installation: Output Options With An M12 Male Connector

    Figure 4-6: Electrical connections for non-Ex devices 1 Power supply 2 Resistor for HART® communication (typically 250 ohms) 3 Optional connection to the grounding terminal 4 Output: 12...30 VDC for an output of 21.5 mA at the terminal 5 Device DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 54: Devices For Hazardous Locations

    • Tighten the cable glands 2. • Close unused cable glands with dummy plugs 3. The diameter of the outer sheath of the electrical cable (for the power supply and current output) must be 6…10 mm or 0.24…0.39¨. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 55: Networks

    Figure 4-8: Point-to-point connection (non-Ex) 1 Address of the device (0 for point-to-point connection) 2 4...20 mA + HART® 3 Resistor for HART® communication (typically 250 ohms) 4 Power supply 5 HART® converter 6 HART® communication software DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 56: Multi-Drop Networks

    1 Address of the device (each device must have a different address in multidrop networks) 2 4 mA + HART® 3 Resistor for HART® communication (typically 250 ohms) 4 Power supply 5 HART® converter 6 HART® communication software www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 57: Start-Up

    • Energize the converter. Devices with the LCD display option only: Devices with the LCD display option only: After 10 seconds the screen will display "DR5400" Devices with the LCD display option only: Devices with the LCD display option only: and the logo of the supplier.
  • Page 58: Digital Display Screen

    Function (2nd Meas. Page). If menu item C6.4.2 1st Value Variable (1st Meas. page) is set to "Level", then the device shows "Level" as the current output percentage in Normal mode (refer to item 1 in the illustration). www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 59: Keypad Buttons

    Normal mode: Change screen (measurement pages 1 and 2 and [Up] the status message page) Program mode: Program mode: Increase value or change parameter Program mode: Program mode: Keypad functions For more data on keypad functions, refer to on page 71. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 60 2 Push the buttons on the keypad. This will operate the device. How to operate the keypad buttons with a bar magnet Figure 5-4: How to operate the keypad buttons with a bar magnet Equipment needed • Bar magnet www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 61: Remote Communication With Pactware

    You can download the latest version of PACTware™ and the DTM from our website. Refer also to the PACTware Consortium site at http://www.pactware.com. Figure 5-5: Screen from the PACTware™ user interface 1 DTM menu 2 Information for device identification 3 Installation parameters menu and menu items DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 62: Remote Communication With The Ams™ Device Manager

    • Store configuration information for each device. • Store and read process data. • Store and read diagnostic status information. • Help plan preventive maintenance to reduce a plant's downtime to a minimum. You can download the DD file from our website. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 63: Operation

    1 One value 2 One value and % bar graph of the scale for the measurement value 3 Two values 4 Two values and % bar graph of the scale for the top measurement value 5 Three values DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 64 10.001 m. If the measurement value is equal to or more than 10 m, set C6.4.5 Format 1st Value to "Automatic". You can change the number of digits and decimal places in the measurement values shown in Normal mode. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 65 [^ ^ ^ ^ ] — [Return] — [> > > > ]+[ ] [Escape] Change screen (measurement pages 1 and 2, and the status [Down] message page) Change screen (measurement pages 1 and 2 and the status [Up] message page) DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 66 It is the distance from the face of the process ft (feet), custom length unit connection (flange face or thread stop) to the surface of the liquid. You cannot change this value in Program mode. Refer also to "Distance" in this table. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 67: Program Mode

    If you did not supply all installation data to the supplier before the delivery, the standard setup procedure in the Quick Setup menu is mandatory. INFORMATION! It is not possible to enter the D Service D Service D Service D Service menu. This menu is for factory calibration and approved personnel only. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 68: Protection Of The Device Settings (Access Levels)

    • Push 2 × [ ], [> > > > ], 5 × [ ], [> > > > ], [ ] and [> > > > ] to go to the menu C7.2 Security. • Push [> > > > ] to enter menu item C7.2.1 Login. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 69 If you de-energize the device and then energize it again, the access level will go back to "User". If you do not touch the keypad for 5 minutes, the device goes back to Normal mode and the access level will go back to "User". DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 70: How To Get Access To The Quick Setup Menu

    • Push [> > > > ] to start the empty spectrum recording procedure. For more data, refer to spectrum recording on page 104. Push [^ ^ ^ ^ ] at the end of each step of the procedure to continue to the next step. • End of the procedure. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 71: Keypad Functions

    Scroll down the sub-menu list (for example, from sub-menu C2.1 to sub-menu C2.2). • Scroll up the menu list (for example, from menu C2 to menu C1). • Scroll up the sub-menu list (for example, from sub-menu C2.2 to sub-menu C2.1). DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 72 Select the parameter and go back to the menu Esc (Escape) If you push these buttons immediately after you change a parameter, the device also ignores this change and goes back to the menu. Down Scroll down the list Scroll up the list www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 73 If the cursor is on a number, this button increases the digit value. If the cursor is on the decimal point, this button moves the decimal point to the right (this increases the value by a factor of 10). DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 74: How To Save Settings Changed In Program Mode

    "Yes" or No", push [^ ^ ^ ^ ] to accept (Yes) or reject (No) the new settings. If you push [^ ^ ^ ^ ] when the screen is set to "Yes" or No", the display goes back to Normal mode. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 75: Menu Overview

    1 The device shows this menu item if you set the menu item A4.1.2.1 to "Stilling Well" 2 The device shows this menu item if you set the menu item A4.2.1.1 to "Partial, Average" or "Partial, Max" DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 76 Spectrum 1 You must enter the "Expert" password in A3 Login or C7.2.1 Login to find and use this menu 2 The device shows this menu item if you make a strapping table in menu C.3 Conversion www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 77 C3.1 Edit Table C3.1 Edit Table C3.1 Edit Table C3.1 Edit Table C3.1.1 Erase Table? C3.1.3 Select Conversion? C3.2 Input Table C3.2 Input Table C3.2 Input Table C3.2 Input Table C3.2.2 Point C3.2.4 Level C3.2.5 Conv. Value DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 78 C4.1 Current Output 1 1 1 1 C4.1.2 0% Range C4.1.3 100% Range C4.1.4 Current Out. Range C4.1.5 Error Function C4.1.7 Low Error Current C4.1.8 High Error Current C4.1.9.2 Trimming / 4mA Trimming C4.1.9.5 Trimming / 20mA Trimming www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 79 Current Out. 1 Var. C5.1.4.2 HART Variables / HART sec./CO2 Var. C5.1.4.3 HART Variables / Tertiary Var. C5.1.4.4 HART Variables / Quaternary Var. C6 Display C6 Display C6.1 Language C6 Display C6 Display C6.2 Backlight C6.3 Contrast DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 80 C7.2 Security C7.2 Security C7.2 Security C7.2.1 Login C7.2.2 Change Password C7.2.3 Reset Passwords C7.2.4 Unlock Extended Range C7.2.5 Unlock SIL C7.3 Errors C7.3 Errors C7.3.1 Message View C7.3 Errors C7.3 Errors C7.3.2.1 Error-Mapping / Sensor: Information www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 81: Function Description

    71 (values in menu items). Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: Operator setting: setting: DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 82 "How to make a filter to remove radar signal interference" on page 114. Minimum access level to do the Minimum access level to do the Minimum access level to do the Minimum access level to do the procedure: procedure: procedure: procedure: Expert www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 83 The device goes to back to Normal mode after 1 hour. Minimum access level to do the Minimum access level to do the Minimum access level to do the Minimum access level to do the procedure: procedure: procedure: procedure: Expert DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 84 The device goes to back to Normal mode after 1 hour. Minimum access level to do the Minimum access level to do the Minimum access level to do the Minimum access level to do the procedure: procedure: procedure: procedure: Expert www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 85 The device goes to back to Normal mode after 1 hour. Minimum access level to do the Minimum access level to do the Minimum access level to do the Minimum access level to do the procedure: procedure: procedure: procedure: Expert DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 86 C7.5 Units C7.5 Units C7.5 Units C7.5 Units. This menu item is only available if you set up a linearization table in menu item C3.1 Edit Table C3.1 Edit Table C3.1 Edit Table C3.1 Edit Table. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 87 It is also possible to do an empty spectrum scan in a partially full tank, if it is not possible to remove all the tank contents. 1 The default value is the measured value at the time that you start the simulation DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 88 = seconds. Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: setting: setting: Expert www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 89 Measuring Mode, you can change this value manually to adjust readings. Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: Expert setting: setting: DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 90 Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: setting: setting: Expert www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 91 [^ ^ ^ ^ ], you go to menu item C3.2.4 Level. Minimum access level to do the procedure: Minimum access level to do the procedure: Minimum access level to do the procedure: Minimum access level to do the procedure: Expert DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 92 20 mA and 100% output to be 4 mA. Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: setting: setting: Expert www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 93 4…20 mA signal and starts HART® multi- drop mode. Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: Expert setting: setting: DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 94 Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: Operator setting: setting: — C5.1.3.4 Cfg. Change This function counts the number of changes Read only Counter to the HART® device settings www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 95 Value, Reflection Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: User setting: setting: DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 96 C6.4.1 Function to "Three Values". Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: User setting: setting: www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 97 C6.5.1 Function to "Two Values", "Two Values & Bar" or "Three Values". Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: User setting: setting: DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 98 Production Date This the date that the manufacturer finished Read only — the device. The date format is: Year-Month- Day. C7.1.9 Calibration Date This the date that the manufacturer Read only — calibrated the device. The date format is: Year-Month-Day. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 99 Enter a text (8 characters maximum) for the — Cst. custom length unit. — C7.5.2.2 Offset Enter an offset value. 0.0 m C7.5.2.3 Factor Enter a factor. Multiply the measured value — by this factor to change m (metres) to the custom length unit. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 100 2 "Lin. Distance" and "Lin. Level" are available if you created a linearized value table in menu C3 Conversion. "Volume" and "Ullage Vol- ume" are available if you created a level-volume table in menu C3 Conversion. "Mass" and "Ullage Mass" are available if you created a level-mass table in menu C3 Conversion. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 101: Further Information On Device Configuration In Program Mode

    [ ] or [ ] for the selection of the length unit (m, Cst., in, ft, mm or Length unit. Make a selection from the list cm). of parameters. • [^ ^ ^ ^ ] to confirm. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 102 Current Out. 1 Var. Current Out. 1 Var. • [^ ^ ^ ^ ] to confirm. illustration 2 shows the position of 0% output as a distance below the flange facing or thread stop of the process connection. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 103 Normal mode. Set • [^ ^ ^ ^ ] to confirm. to "No" to cancel the changes to the device settings and go back to Normal mode. Set to "Back" to stay in Program mode. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 104: Empty Spectrum Recording

    Enter the password used at this time for the "Expert" access level. If it is the default 5 × [ ], [> > > > ] and 8 × [ ] password, enter "0058". • [^ ^ ^ ^ ] to confirm. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 105 Save spectrum? If you set the menu item to "Yes", the device will keep this empty ("No" or "Yes"). spectrum recording. If you set the menu • [^ ^ ^ ^ ] to confirm. item to "No", the device will reject this data. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 106: Hart® Network Configuration

    • Enter the value 000 and push [^ ^ ^ ^ ] to confirm. • Push [^ ^ ^ ^ ] again and again to go back to the Save Configuration? Save Configuration? screen. Save Configuration? Save Configuration? www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 107: Distance Measurement

    CAUTION! If C4.1.1 Current Out. 1 Var. is set to "Distance" and C4.1.2 0% Range (standard scale) is set in the blocking distance, then the device will not be able to use the full current output range. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 108 C6.4.2 and C6.5.2 (1st Value Variable) and menu C1 Install. Parameters. If you change C1.10 Reference Offset, then we recommend that you change C6.4.3 / C6.5.3 (0% Range) and C6.4.4 / C6.5.4 (100% Range) by the same quantity. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 109: Level Measurement

    CAUTION! If C4.1.1 Current Out. 1 Var. is set to "Level" and C4.1.3 100% Range (standard scale) is set in the blocking distance, then the device will not be able to use the full current output range. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 110 C6.4.2 and C6.5.2 (1st Value Variable) and menu C1 Install. Parameters. If you change C1.11 Tank Bottom Offset, then we recommend that you change C6.4.3 / C6.5.3 (0% Range) and C6.4.4 / C6.5.4 (100% Range) by the same quantity. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 111: How To Configure The Device To Measure Volume Or Mass

    Normal mode. The device will give more accurate volume readings if you give more conversion data in these areas: • Surfaces with curves. • Sudden changes in the cross section. Refer also to the illustration that follows: DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 112 "Yes" or No", push [^ ^ ^ ^ ] to accept (Yes) or reject (No) the new settings. If you push [^ ^ ^ ^ ] when the screen is set to "Yes", the device will delete the data for the strapping table and go back to Normal mode. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 113: How To Measure Correctly In Tanks With Curved Or Conical Bottoms

    • Select Yes Yes and push [^ ^ ^ ^ ]. The device will go back to Normal mode. INFORMATION! For more data on menu items, refer to Function description on page 81 table C: Full Setup. – DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 114: How To Make A Filter To Remove Radar Signal Interference

    INFORMATION! For more data on empty spectrum scans, refer to Function description on page 81 table A. – Quick Setup menu (menu item A4.2). www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 115: Status Messages And Diagnostic Data

    Normal mode: device status symbol If the device status changes, the device shows a status symbol in the top left corner of the display screen in Normal mode: Figure 6-11: Device status: Normal mode 1 Device status symbol (NAMUR NE 107) DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 116 1 Device status letter code (NAMUR NE 107). In this example, M = Maintenance required. 2 Description of error If the device shows an error message, refer to the table that follows for more data and to find a solution to a problem. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 117 Inconsistent Parameters Internal bus communication error. De-energize and then energize the device again. Sensor Comm. Error Internal bus communication error or hardware failure. If the message is shown again, tell the supplier. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 118 If the message is shown again, tell the supplier. C C C C Electronics Electronics Electronics Electronics FW Update A firmware update of the Wait for the firmware update to converter module continues. finish. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 119 S S S S Electronics Electronics Electronics Electronics Elec. Temp. Out Of Spec. The temperature of the converter Make sure that the device is is not in the specified limits. operated in the permitted ambient temperature range. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 120 If the message is shown again, tell the supplier. Empty Spectrum invalid The empty spectrum recording Do a new empty spectrum does not agree with the process recording. conditions at this time (e.g. the tank height was changed). www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 121 Microwave Lock Error Microwave Sweep Duration Error Microwave Supply Voltage Error 1 DM = data manager 2 CO = current output 3 This error message is shown if the device is in SIL mode. CO = current output. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 122: Service

    O-rings are correctly greased or, if it is necessary, replaced. For more data Spare parts about the replacement of the O-rings, refer to on page 173. Figure 7-1: Maintenance of the O-rings 1 Display cover 2 Terminal compartment cover www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 123: How To Clean The Top Surface Of The Device

    How to use the purge The device is colder than other Continuous use. Use low-pressure gas to remove condensation from elements in the process. It is the antenna. possible that there will be condensation in the antenna. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 124: Service Warranty

    For more precise information, please contact your local sales office. 7.5 Returning the device to the manufacturer 7.5.1 General information This device has been carefully manufactured and tested. If installed and operated in accordance with these operating instructions, it will rarely present any problems. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 125 • such dangerous substances, to enclose a certificate with the device confirming that it is safe to handle and stating the • product used. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 126: Form (For Copying) To Accompany A Returned Device

    The user must dispose of the WEEE to a designated collection point for the recycling of WEEE or send them back to our local organisation or authorised representative. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 127: Technical Data

    1 Transmitter 2 Mixer 3 Antenna 4 Distance to product surface, where change in frequency is proportional to distance 5 Differential time delay, Δt 6 Differential frequency, Δf 7 Frequency transmitted 8 Frequency received 9 Frequency 10 Time DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 128 CAUTION! "TBF FULL" AND "TBF AUTO" MODES It is important to enter the correct dielectric constant value in menu item C2.2 Epsilon R Product. If this value is incorrect, the device will not measure level accurately. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 129: Technical Data

    Refer also to "Measuring accuracy" on page 135 Min. tank height 0.2 m / 8¨ Recommended minimum Antenna extension length + antenna length + 0.1 m / 4¨ blocking distance Min. distance for reflection 1 m / 3.3 ft measurement DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 130 Metallic Horn antenna: Metallic Horn antenna: Metallic Horn antenna: -1…16 barg / -14.5…232 psig Subject to the process connection used and the process connection temperature. Guidelines for maximum operating pressure For more data, refer to on page 137. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 131 This is the maximum range. The feedthrough temperature limits must agree with the temperature limits of the gasket material and antenna type. Cable gland Standard: none Options: Plastic (Non-Ex: black, Ex i-approved: blue); nickel-plated brass; stainless steel; M12 (4-pin connector) Weather protection (Option) Stainless steel (1.4404 / 316L) DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 132 Load Max. ±15 mm / 0.6¨ for the full temperature range Digital temperature drift Multi-drop operation Yes. Current output = 4 mA. Enter Program mode to change the polling address (1...63). Available drivers FC475, AMS, PDM, FDT/DTM www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 133 Ex ia IIIC T85°C...T*°C Da (Canada); Zone 21, AEx ia tb [ia Da] IIIC T85°C...T*°C Db (US) – antenna suitable for Zone 20 Ex ia tb [ia Da] IIIC T85°C...T*°C Db (Canada) – antenna suitable for Zone 20 DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 134 2 HART® is a registered trademark of the HART Communication Foundation 3 T* = T5 or T4. For more data, refer to the related Ex approval certificate. 4 T*°C = 100°C or 130°C. For more data, refer to the related Ex approval certificate. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 135: Measuring Accuracy

    Y: Measuring accuracy [+yy inches / -yy inches] 1 Minimum recommended blocking distance = antenna extension length + antenna length + 3.94¨ INFORMATION! To calculate the accuracy at a given distance from the antenna, refer to Technical data on page (measuring accuracy). DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 136: Minimum Power Supply Voltage

    Hazardous Location (Ex d / XP/NI) approved devices Figure 8-5: Minimum power supply voltage for an output of 21.5 mA at the terminals (Hazardous Location approval (Ex d / XP/NI)) X: Power supply U [V DC] Y: Current output load R [Ω] www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 137: Guidelines For Maximum Operating Pressure

    1 Process pressure, p [barg] 2 Process connection temperature, T [°C] 3 Process pressure, p [psig] 4 Process connection temperature, T [°F] 5 Threaded connection, G (ISO 228-1) 6 Threaded connection, G (ISO 228-1). Flange connection, PN40. 7 Flange connection, PN16 DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 138 There is a CRN certification option for devices with process connections that agree with ASME standards. This certification is necessary for all devices that are installed on a pressure vessel and used in Canada. Figure 8-8: Pressure / temperature de-rating (ASME B16.5), flange and threaded connections, in °C and barg www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 139 1 Process pressure, p [barg] 2 Process connection temperature, T [°C] 3 Process pressure, p [psig] 4 Process connection temperature, T [°F] 5 Threaded connection, NPT (ASME B1.20.1). Flange connection, Class 300. 6 Flange connection, Class 150 DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 140: Dimensions And Weights

    The diameter of the outer sheath of the cable must be 7 … 12 mm or 0.28 … 0.47 ¨ Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 141 DN150/6¨ 5.94 11.14 19.29 26.57 5.51 DN200/8¨ 5.94 11.14 26.06 33.35 7.48 1 This is the dimension without the antenna extension option. A maximum of 10 antenna extensions are available. Each antenna exten- sion is 4.1¨ long. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 142 The diameter of the outer sheath of the cable must be 7 12 mm or 0.28 0.47 • … … ¨ Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 143 18.78...19.29 26.77...27.76 5.51 DN200/8¨ 5.94 7.99...8.49 25.55...26.06 33.54...34.53 7.48 1 These are the minimum and maximum values without the antenna extension option. A maximum of 10 antenna extensions are avail- able. Each antenna extension is 4.1¨ long. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 144 The diameter of the outer sheath of the cable must be 7 … 12 mm or 0.28 … 0.47 ¨ Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 145 19.13 26.57 28.86 5.51 DN200/8¨ 5.94 8.46 9.72 25.87 33.35 35.59 7.48 1 This is the dimension without the antenna extension option. A maximum of 10 antenna extensions are available. Each antenna exten- sion is 4.1¨ long. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 146 The diameter of the outer sheath of the cable must be 7 … 12 mm or 0.28 … 0.47 ¨ • Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 147 2.91 DN100/4¨ 5.94 7.28 6.30 13.58 3.70 DN150/6¨ 5.94 7.28 8.50 15.78 5.67 1 This is the dimension without the antenna extension option. A maximum of 5 antenna extensions are available. Each antenna extension is 4.1¨ long. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 148 The diameter of the outer sheath of the cable must be 7 … 12 mm or 0.28 … 0.47 ¨ Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 149 1 These are the minimum and maximum values without the antenna extension option. A maximum of 5 antenna extensions are available. Each antenna extension is 4.1¨ long. 2 If the device has the PP flange protection option DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 150 The diameter of the outer sheath of the cable must be 7 … 12 mm or 0.28 … 0.47 ¨ Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 151 8.66 6.26 13.66 14.92 3.70 DN150/6¨ 5.94 7.40 8.66 8.54 15.94 17.20 5.67 1 This is the dimension without the antenna extension option. A maximum of 5 antenna extensions are available. Each antenna extension is 4.1¨ long. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 152 1 Front view (with weather protection closed) 2 Left side (with weather protection closed) 3 Rear view (with weather protection closed) Weather protection: Dimensions and weights Dimensions Weights [kg] [mm] [inch] [mm] [inch] [mm] [inch] [kg] [lb] Weather 6.97 6.02 8.50 protection www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 153 Flange plate option, DN100 PP Drop antenna +0.2 +0.44 Flange plate option, DN150 PP Drop antenna +0.3 +0.66 1 Standard length = without antenna extensions 2 This option is for Metallic Horn and Drop antennas 3 This option is for Metallic Horn antennas DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 154: Description Of Hart Interface

    An FSK or HART® modem is included in field devices and manual control units. It is necessary to have an external modem for PC-supported workstations. The external modem is connected to the serial or USB interface. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 155: Software History

    • as Multi-Drop connection with 2-wire connection. 9.3.1 Point-to-Point connection – analogue / digital mode Point-to-Point connection between the signal converter and the HART® Master. The current output of the device is passive. Point-to-point connection Also refer to on page 55. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 156: Multi-Drop Connection (2-Wire Connection)

    System and software requirements for the Field Communicator • System card that includes the "Easy Upgrade Option" • Field Communicator Easy Upgrade Programming Utility • HART® Device Description file For more data, refer to the Field Communicator User’s Manual. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 157: Operation

    AMS and operating using the local keyboard. The service menu parameters are not supported and simulation is only possible for current outputs. The online help for each parameter contains its function number as a reference to the local device display. DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 158: Field Device Tool / Device Type Manager (Fdt / Dtm)

    Refer to the online help in SIMATIC PDM to find the function number of each menu item. This function number agrees with the function number in the device menus. Use the same procedure for the protection of parameters in the supervisor menu. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 159: Hart® Menu Tree For Ams

    9.9.1 Overview AMS menu tree (positions in menu tree) Configure / Setup Quick Setup General Security Units Application Full Setup Process Output Display Device Hart Calibration Service Information Device Diagnostics Device Status Actual Values Simulation Test/Reset Information Process Variables Measured Values Inputs/Outputs DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 160: Ams Menu Tree (Details For Settings)

    Range / 100% Range 2nd Measurement Function / 1st Value Variable / Page Format 1st Value / 2nd Value Variable / Format 2nd Value / 3rd Value Variable Format 3rd Value / 0% Range / 100% Range www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 161 / Number of response preambles Service Calibration Calibration Current Output 1 Sensor Manual Correction Offset / Manual Correction Factor / Correction Offset / Correction Factor Rd, Opt Correction Offset Extended Rd, Opt Correction Factor Extended DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 162: Hart® Menu Tree For Pdm

    / TV / QV 9.10 HART® menu tree for PDM Abbreviations of the following tables: • Optional, depending on device version and configuration • Read only Cust • Custody lock protection • Local PDM, affects only PDM views www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 163: Overview Pdm Menu Tree (Positions In Menu Tree)

    Identification & Info Service Calibration Calibration Sensor Overview: View Menu Measured Value Input / Outputs Overview: Diagnosis Device Status Condensed Status (NE 107) Standard Additional Cluster Check Actual Values Simulation Process Variables Device Status Test / Reset Information DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 164: Pdm Menu Tree (Details For Settings)

    / 100% Range 2nd Measurement Function / 1st Value Variable / Format 1st Value / Page 2nd Value Variable / Format 2nd Value / 3rd Value VariableOpt / Format 3rd Value / 0% Range / 100% Range www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 165 / Level Linearization / Volume Opt, Rd Opt, Rd Opt, Rd Opt, Rd Mass / Distance Linearization / Ullage / Ullage Mass Input / Outputs / PV % Range / PV output current / SV / TV / QV DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 166 / Long Tag / Serial Number / Manufacturer / Device Name / V Number / Electronic Revision / Field Device Revision / Software Revision / Hardware Revision / Electronics Serial / Production Date / Calibration Date / Operating Time www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 167: Appendix

    Make a selection from each column to get the full order code. DR5400 4 1 DR5400 - 24 GHz radar (FMCW) level transmitter for liquids in basic process applications (up to DR5400 - 24 GHz radar (FMCW) level transmitter for liquids in basic process applications (up to...
  • Page 168 A Russian B Czech C Turkish D Polish DR5400 DR5400 4 Order code (complete this code on the pages that follow) Order code (complete this code on the pages that follow) DR5400 DR5400 Order code (complete this code on the pages that follow) Order code (complete this code on the pages that follow) www.drexelbrook.com...
  • Page 169 H 420 mm (17¨) for PP Drop antenna / PP K 525 mm (21¨) for PP Drop antenna / PP DR5400 DR5400 4 Order code (complete this code on the pages that Order code (complete this code on the pages that...
  • Page 170 DN150 PN40 – Type B1 P G 1 R E 1 DN200 PN16 – Type B1 DR5400 DR5400 4 Order code (complete this code on the pages Order code (complete this code on the pages DR5400 DR5400 Order code (complete this code on the pages...
  • Page 171 Without Purging system with 1/8 NPTF connection DR5400 DR5400 DR5400 DR5400 4 Order code (complete this code on Order code (complete this code on Order code (complete this code on Order code (complete this code on the pages that follow)
  • Page 172 Weather protection + Stainless steel Tag plate (18 characters max.) DR5400 DR5400 DR5400 DR5400 4 Order code Order code Order code Order code 1 Pending 2 Pending. DIP = Dust Ignition Proof. 3 This housing option has Ex ia and Ex ic approvals. The Ex d approval for this option is pending.
  • Page 173: Spare Parts

    We supply spare parts for this device. When you send an order for a mechanical spare part, use the reference numbers in the table that follows. When you send an order for an electronic spare Order code part, refer to on page 167 and use the DR5400 order code. Mechanical spare parts Description Quantity...
  • Page 174 (8) + cover stop (1) XFDX010101 (11) (11) Stainless steel blind cover (11) + gasket (8) (8) + cover stop (1) XFDX010201 Aluminium display cover(9) (9) + gasket (8) XFDX010301 Stainless steel display cover (9) (9) + gasket (8) XFDX010401 www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 175 Cable entry / ½ NPT nickel-plated brass cQPSus (5) XFDX050900 Cable entry / ½ NPT stainless steel non-Ex (GP) / Ex i (5) XFDX051000 Cable entry / ½ NPT stainless steel Ex d (5) XFDX051100 Cable entry / ½ NPT stainless steel cQPSus (5) XFDX051200 DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 176: Accessories: General Items

    4 Display extractor, magnet and cover wrench Item Description Quantity Part reference Weather protection XFDX060100 Viator RS232 / HART converter XFDX060200 Viator USB / HART converter XFDX060300 Display extractor, magnet and cover wrench XFDX060400 — USB / 24 V DC power supply XFDX060500 www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 177 Disc with holes, drilled according to DN100 PN2.5...PN40 / 4¨ 150 lb XF70000011 Disc with holes, drilled according to DN150 PN2.5...PN40 / 6¨ 150 lb XF70000013 Disc with holes, drilled according to DN200 PN2.5...PN40 / 8¨ 150 lb XF70000014 DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 178 Other accessories for process connections 316L wall-mounted bracket for G 1½ process connection on level XF70000059 transmitter 316L hanging, orientable bracket (max. tilt 45°) XF70000067 1 For more data, refer to the "Technical data: Dimensions and weights" section in this document www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 179 Height from the bottom of the tank (user-defined) to the surface of the top product (Tank height – distance). See the diagrams at the end of this section. Mass Mass Total mass of tank contents. Mass Mass DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 180 TBF mode uses the reflection of the tank bottom to indirectly measure the level of the tank contents. Ullage volume Ullage volume Ullage volume Ullage volume Unfilled volume. See the diagrams at the end of this section. Volume Volume Volume Volume Total volume of tank contents. www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 181 APPENDIX DR5400 Figure 10-4: Measurement definitions: distance 1 Distance 2 Blocking distance 3 Flange facing 4 Gas (Air) 5 Tank height 6 Ullage volume or mass Figure 10-5: Measurement definitions: level 1 Level 2 Volume or mass DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 182 NOTES DR5400 www.drexelbrook.com DR5400-PM-English-Issue 1...
  • Page 183 NOTES DR5400 DR5400-PM-English-Issue 1 www.drexelbrook.com...
  • Page 184 AMETEK Drexelbrook makes no warranty of any kind with regard to the material contained in this manual, including, but not limited to, implied warranties or fitness for a particular purpose. Drexelbrook shall not be liable for errors contained herein or for incidental or consequential damages in connection with the performance or use of material.

Table of Contents