JC LAB Bimc-12N1000 Operation Manual

Biological microscope

Advertisement

Quick Links

I N T E R N A T I O N A L
Biological microscope
Bimc-12N1000
®
OPERATION MANUAL
GUIDA UTENTE
MANUAL DE INSTRUCCIONES
MANUEL D'INSTRUCTIONS
BEDIENUNGSANLEITUNG
取扱説明書
(PDF版のみ)
產品說明書
(只提供pdf版本)
JC LAB Microscope - JAPAN
www.jc-lab.jp
(Solo versione PDF)
-
info@jc-lab.jp
(Solo versió n PDF)
(Version PDF uniquement)
(Nur PDF-Version)
Ver.1.4.0

Advertisement

Table of Contents
loading

Summary of Contents for JC LAB Bimc-12N1000

  • Page 1 I N T E R N A T I O N A L Ver.1.4.0 Biological microscope Bimc-12N1000 OPERATION MANUAL GUIDA UTENTE (Solo versione PDF) MANUAL DE INSTRUCCIONES (Solo versió n PDF) MANUEL D’INSTRUCTIONS (Version PDF uniquement) BEDIENUNGSANLEITUNG (Nur PDF-Version) 取扱説明書 (PDF版のみ) 產品說明書 (只提供pdf版本) JC LAB Microscope - JAPAN www.jc-lab.jp info@jc-lab.jp...
  • Page 2: Table Of Contents

    INDEX 1.0 Copyright Page 1 - 3 2.0 Microscope at a Glance Page 4 3.0 Introduction Page 5 4.0 Unpacking and Assembly Page 5 5.0 Microscope Accessories Page 6 - 7 6.0 Using the Microscope Page 8 - 9 7.0 Maintenance Page 10 8.0 Troubleshooting Page 11...
  • Page 3: Copyright

    © 2012 by JC LAB Corporation. All rights reserved. Under the copyright law, this manual cannot be reproduced in any form without the prior written permission of JC LAB. No patent liability is assumed, with respect to the use of the information contained herein.
  • Page 4 Because Wireless products operate within the guidelines found in radio frequency safety standards and recommendations, JC LAB believes Wireless products is safe for use by consumers. These standards and recommendations reflect the consensus of scientific community and result from deliberations of panels and committees of scientists who continually review and interpret the extensive research literature.
  • Page 5 JC LAB Support If you require any additional help your devices or if you are having problems operating devices, you may need to contact JC LAB for additional technical assistance. Before you call Some problem you experience may be related to software, apps or the operating system so it is importance that you investigate other sources of assistance first.
  • Page 6: Microscope At A Glance

    2.0 Microscope at a Glance Microscope at a Glance 9, 10, 11 12 & 15 5 & 6 & 14 BIMC-12N1000 1. Eyepiece 9. Fuse Box 2. Objective Lens 10. On/Off Switch 3. Binocular Head 11. Power Plug 4. Fine Adjustment Knob 12.
  • Page 7: Introduction

    It is built to high optical and mechanical standards and to withstand daily classroom and laboratory use. JC LAB reminds you that this manual contains important information on safety and maintenance, and that it must therefore be made accessible to the instrument users.
  • Page 8: Microscope Accessories

    5.0 Microscope Accessories J-Scope 5G Wi-Fi Eyepiece (Digital Camera)-Overview The BIMC-A03A-W2 is known around the globe for their ease-of-use and adaptability to a number of applications. The JC Cam’s unique “All In One Box” design, assures each user that this camera can fit almost any microscope whether it’s for Educational, Industrial or Clinical use.
  • Page 9 5.0 Microscope Accessories Stage Micrometer for Microscope Lens Cleaning Tissue for slide cleaning Calibration with NIST certification TOO-155E BIMC-S09A MiniPC for JC Cam series Wifi Digital Drying Cabinet, Cap. 60L eyepiece to screen on the TV BIMC-MIPC06 CHD-60 Slide Folder, hold 20pcs of slide MCS-SL01A Page 7...
  • Page 10: Using The Microscope

    Once the microscope has been setup in its working location with all of the components correctly installed, it is ready for use. Your BIMC-12N1000 is a precision instrument designed to last a lifetime. always handle your microscope with care and avoid abrupt motion vibration and hock.
  • Page 11 6.0 Using the Microscope 3. Selecta lower power "scanning" objective like the 4X or the 10X to find the area of interest on the specimen quickly. Be sure the objective "clicks" into place when you rotate the objective nosepiece. Caution: The maximum light intensity when using the 4x and 10x can damage the eyes! 4.
  • Page 12: Maintenance

    7.0 Maintenance 7.1 Microscope environment This Microscope is recommended to be used in a clean, dry and shock free environment with a temperature of 10°-36°C and a maximum relative humidity of 80 % (non condensing). Use a dehumidifier if needed. To think about when and after using the microscope - The microscope should always be kept vertically when moving it and be careful so that no moving parts, such as the eyepieces, fall out...
  • Page 13: Troubleshooting

    8.0 Troubleshooting Review the information in the table below to troubleshoot operating problems. PROBLEM CAUSE SOLUTION I. Optical Section: LED operates, but field of view remains dark. Battery is lower. Plug Power supply to charge the microscope Brightness is too low Set brightness to a proper level Dirt or dust is visible in the field of view.
  • Page 14: Electrics

    9.0 Electrics Universal Power: 220 V, 50/60 Hz, DC 5V 2A Lamp: 5W Cold Light s-LED Fuse: T1A 10.0 Recycling and Recovery Art.13 Dlsg 25 july 005 N°151. “According to directives 2002/95/EC, 2002/96/ EC and 2003/108/EC relating to the reduction in the use of hazardous substances in electrical and electronic equipment and waste disposal.”...

Table of Contents