JC LAB Bimc-04ns05 Operation Manual

Zoom stereomicroscope

Advertisement

Quick Links

I N T E R N A T I O N A L
Zoom Stereomicroscope
Bimc-04ns05
®
OPERATION MANUAL
GUIDA UTENTE
MANUAL DE INSTRUCCIONES
MANUEL D'INSTRUCTIONS
BEDIENUNGSANLEITUNG
取扱説明書
(PDF版のみ)
產品說明書
(只提供pdf版本)
JC LAB Microscope - JAPAN
www.jc-lab.jp
(Solo versione PDF)
-
info@jc-lab.jp
(Solo versió n PDF)
(Version PDF uniquement)
(Nur PDF-Version)
Ver.2.1.6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bimc-04ns05 and is the answer not in the manual?

Questions and answers

Summary of Contents for JC LAB Bimc-04ns05

  • Page 1 I N T E R N A T I O N A L Ver.2.1.6 Zoom Stereomicroscope Bimc-04ns05 OPERATION MANUAL GUIDA UTENTE (Solo versione PDF) MANUAL DE INSTRUCCIONES (Solo versió n PDF) MANUEL D’INSTRUCTIONS (Version PDF uniquement) BEDIENUNGSANLEITUNG (Nur PDF-Version) 取扱説明書 (PDF版のみ) 產品說明書 (只提供pdf版本) JC LAB Microscope - JAPAN www.jc-lab.jp info@jc-lab.jp...
  • Page 2: Table Of Contents

    INDEX 1.0 Copyright Page 1 - 3 2.0 Microscope at a Glance Page 4 3.0 Introduction Page 5 4.0 Unpacking and Assembly Page 5 5.0 Microscope Accessories Page 6 - 7 6.0 Using the Microscope Page 8 - 9 7.0 Maintenance Page 10 8.0 Troubleshooting Page 11...
  • Page 3: Copyright

    © 2012 by JC LAB Corporation. All rights reserved. Under the copyright law, this manual cannot be reproduced in any form without the prior written permission of JC LAB. No patent liability is assumed, with respect to the use of the information contained herein.
  • Page 4 Because Wireless products operate within the guidelines found in radio frequency safety standards and recommendations, JC LAB believes Wireless products is safe for use by consumers. These standards and recommendations reflect the consensus of scientific community and result from deliberations of panels and committees of scientists who continually review and interpret the extensive research literature.
  • Page 5 JC LAB Support If you require any additional help your devices or if you are having problems operating devices, you may need to contact JC LAB for additional technical assistance. Before you call Some problem you experience may be related to software, apps or the operating system so it is importance that you investigate other sources of assistance first.
  • Page 6: Microscope At A Glance

    2.0 Microscope at a Glance Microscope at a Glance BIMC-12A 1. Zoom Adjustment Knob 7. Stage Plate & Transmitted LED 2. Focus Adjustment Knob 8. Microscope Body 3. Reflected LED 9. Body Clamping Knob 4. Transmitted & Reflected LED 10. Eyepiece light intensity switch 5.
  • Page 7: Introduction

    It is built to high optical and mechanical standards and to withstand daily classroom and laboratory use. JC LAB reminds you that this manual contains important information on safety and maintenance, and that it must therefore be made accessible to the instrument users.
  • Page 8: Microscope Accessories

    5.0 Microscope Accessories J-Scope 5G Wi-Fi Eyepiece (Digital Camera)-Overview The BIMC-A03A-W2 is known around the globe for their ease-of-use and adaptability to a number of applications. The JC Cam’s unique “All In One Box” design, assures each user that this camera can fit almost any microscope whether it’s for Educational, Industrial or Clinical use.
  • Page 9 5.0 Microscope Accessories Stage Micrometer for Microscope Lens Cleaning Tissue for slide cleaning Calibration with NIST certification TOO-155E BIMC-S09A MiniPC for JC Cam series Wifi Digital Drying Cabinet, Cap. 60L eyepiece to screen on the TV BIMC-MIPC06 CHD-60 Slide Folder, hold 20pcs of slide MCS-SL01A Page 7...
  • Page 10: Using The Microscope

    Once the microscope has been setup in its working location with all of the components correctly installed, it is ready for use. Your BIMC-04NS05 is a precision instrument designed to last a lifetime. always handle your microscope with care and avoid abrupt motion vibration and hock.
  • Page 11 6.0 Using the Microscope 2. Using the focusing knob, focus the sample using the highest magnification strength. If the sample cannot be brought into focus, adjust the height of the microscope along the column. Remember to tighten the locking screw and support collar after adjusting the height of the microscope.
  • Page 12: Maintenance

    7.0 Maintenance 7.1 Microscope environment This Microscope is recommended to be used in a clean, dry and shock free environment with a temperature of 10°-36°C and a maximum relative humidity of 80 % (non condensing). Use a dehumidifier if needed. To think about when and after using the microscope - The microscope should always be kept vertically when moving it and be careful so that no moving parts, such as the eyepieces, fall out...
  • Page 13: Troubleshooting

    8.0 Troubleshooting Review the information in the table below to troubleshoot operating problems. PROBLEM CAUSE SOLUTION I. Optical Section: LED operates, but field of view remains dark. Power Plug no connect Put the plug to the microscope Brightness is too low Set brightness to a proper level Dirt or dust is visible in the field of view.
  • Page 14: Electrics

    9.0 Electrics Universal Power: 220 V, 50/60 Hz, DC 5V 2A Lamp: Upper (Reflected) and Lower (Transmitted) 5W Cold Light s-LED Fuse: T1A 10.0 Recycling and Recovery Art.13 Dlsg 25 july 005 N°151. “According to directives 2002/95/EC, 2002/96/ EC and 2003/108/EC relating to the reduction in the use of hazardous substances in electrical and electronic equipment and waste disposal.”...